Experimental Investigation of Reduced Beam Section Connections by Use of Web Openings
Authors:
- Jong Won ParkJPJong Won Park
- In Kyu HwangIHIn Kyu Hwang
Open Access
- 30 June 2003
- journal article
- Published by American Institute of Steel Construction in Engineering Journal
- Vol. 40 (2) , 77-88
Abstract
Since the 1994 Northridge Earthquake, a wide variety of different moment connections have been developed to provide high ductility and reliable performance. Most of these moment connections incorporate the reinforcement at the connection using cover plates, ribs or haunches (Engelhardt, Sabol, Aboutaha, and Frank, 1995; Engelhardt and Sabol, 1998; Uang and Bondad, 1996; Uang, Bondad, and Lee, 1998; Whittaker and Gilani, 1996). The purpose of the reinforcement at the connection was to force the plastic hinge away from the face of the column, where premature fractures can occur due to potential weld defects, stress concentrations, etc. The reinforced connections generally showed good performance. However, reinforcing the connection may increase its fabrication costs. Moreover, there were some concerns with respect to reliability resulting from the very large weld for reinforcement. A total of six large-scale tests were performed on single cantilever type test specimens. The specimens were subjected to slowly applied cycles of loads. A test program was conducted on Reduced Beam Section connections by use of beam web openings. The test specimens showed good performance overall, although yielding occurred at lower levels of rotation and strength degradation was worse than for reduced beam flange type connections (dogbone connections).Keywords
This publication has 9 references indexed in Scilit:
- Panel Zone Yielding in Steel Moment ConnectionsEngineering Journal, 2000
- Experimental Investigation of Dogbone Moment ConnectionsEngineering Journal, 1998
- Reinforcing of steel moment connections with cover plates: benefits and limitationsEngineering Structures, 1998
- Cyclic performance of haunch repaired steel moment connections: experimental testing and analytical modelingEngineering Structures, 1998
- Steel Moment Frames with Ductile Girder Web OpeningEngineering Journal, 1998
- Ultimate Strength Considerations for Seismic Design of the Reduced Beam Section (Internal Plastic Hinge)Engineering Journal, 1997
- Ductile Steel Beam-to-Column Connections for Seismic ResistanceJournal of Structural Engineering, 1996
- Panel zone flexibility in seismic moment jointsJournal of Constructional Steel Research, 1987
- Shear in Beam-Column Joints in Seismic Design of Steel FramesEngineering Journal, 1978