Large-scale fire test of unprotected cellular beam acting in membrane action
Authors:
- 1 July 2012
- journal article
- Published by Emerald Publishing in Proceedings of the Institution of Civil Engineers - Structures and Buildings
- Vol. 165 (7) , 327-334
Abstract
This paper describes a full-scale fire test performed recently on a composite floor for analysing the possibility for tensile membrane action to develop when unprotected steel beams in the central part of the floor are made of cellular beams. The natural fire was created by a wood crib fire load of 700 MJ/m2and the 9 m × 15 m floor survived the fire, which peaked at 1000°C and lasted for about 90 min. Blind predictions of the air temperature development by the software ‘Ozone' and of the structural behaviour by the software ‘Safir', which proved quite satisfactory, are also described.Keywords
This publication has 5 references indexed in Scilit:
- Behaviour of concrete floor slabs at ambient and elevated temperaturesFire Safety Journal, 2007
- Performance of cellular composite floor beams at elevated temperaturesFire Safety Journal, 2007
- SAFIR: A Thermal and Structural Program for Modeling Structures Under FireEngineering Journal, 2005
- A tool to design steel elements submitted to compartment fires—OZone V2. Part 1: pre- and post-flashover compartment fire modelFire Safety Journal, 2003