The Ability of a Novel Algorithm for Automatic Estimation of the Respiratory Variations in Arterial Pulse Pressure to Monitor Fluid Responsiveness in the Operating Room
Authors:
- Maxime CannessonMCMaxime Cannesson
- Juliette SliekerJSJuliette Slieker
- Olivier DesebbeODOlivier Desebbe
- Christian BauerCBChristian Bauer
- Pascal ChiariPCPascal Chiari
- Roland HénaineRHRoland Hénaine
- Jean-Jacques LehotJLJean-Jacques Lehot
- 1 April 2008
- journal article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 106 (4) , 1195-1200
Abstract
Respiratory variations in arterial pulse pressure (deltaPP(man)) are accurate predictors of fluid responsiveness in mechanically ventilated patients. However, they cannot be continuously monitored. In our study, we assessed the clinical utility of a novel algorithm for automatic estimation of deltaPP (deltaPP(auto)). We studied 25 patients referred for coronary artery bypass grafting. DeltaPP(auto) was continuously displayed using a method based on automatic detection algorithms, kernel smoothing, and rank-order filters. All patients were under general anesthesia, mechanical ventilation, and were also monitored with a pulmonary artery catheter. DeltaPP(man) and deltaPP(auto) were recorded simultaneously at eight steps during surgery including before and after intravascular volume expansion (500 mL hetastarch). Responders to volume expansion were defined as patients whose cardiac index increased by more than 15% after volume expansion. Agreement between deltaPP(man) and deltaPP(auto) over the 200 pairs of collected data was 0.7% +/- 3.4% (mean bias +/- SD). Seventeen patients were responders to volume expansion. A threshold deltaPP(man) value of 12% allowed discrimination of responders to volume expansion with a sensitivity of 88% and a specificity of 100%. A threshold deltaPP(auto) value of 10% allowed discrimination of responders to volume expansion with a sensitivity of 82% and a specificity of 88%. DeltaPP(auto) is strongly correlated to deltaPP(man) is an accurate predictor of fluid responsiveness, and allows continuous monitoring of deltaPP. This novel algorithm has potential clinical applications.Keywords
This publication has 28 references indexed in Scilit:
- Meta-analysis of hemodynamic optimization: relationship to methodological qualityCritical Care, 2005
- Intraoperative oesophageal Doppler guided fluid management shortens postoperative hospital stay after major bowel surgeryBritish Journal of Anaesthesia, 2005
- Prediction of fluid responsiveness in patients during cardiac surgeryBritish Journal of Anaesthesia, 2004
- Goal-directed Intraoperative Fluid Administration Reduces Length of Hospital Stay after Major SurgeryAnesthesiology, 2002
- Randomised controlled trial investigating the influence of intravenous fluid titration using oesophageal Doppler monitoring during bowel surgery*Anaesthesia, 2002
- Randomized controlled trial to investigate influence of the fluid challenge on duration of hospital stay and perioperative morbidity in patients with hip fractures † †These findings were presented in part at the 13th Annual Meeting of the European Society of Intensive Care Medicine, Rome 2000.British Journal of Anaesthesia, 2002
- Respiratory Changes in Aortic Blood Velocity as an Indicator of Fluid Responsiveness in Ventilated Patients With Septic ShockChest, 2001
- Relation between Respiratory Changes in Arterial Pulse Pressure and Fluid Responsiveness in Septic Patients with Acute Circulatory FailureAmerican Journal of Respiratory and Critical Care Medicine, 2000
- Systolic Pressure Variation as a Guide to Fluid Therapy in Patients with Sepsis-induced HypotensionAnesthesiology, 1998
- Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: randomised controlled trialBMJ, 1997