Radiofrequency Catheter Ablation:
Authors:
- 30 June 2003
- journal article
- website
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 26 (7p1) , 1438-1445
Abstract
The success and safety of standard catheter radiofrequency ablation may be limited for ablation of atrial fibrillation and ventricular tachycardia. The aim of this study was to characterize and compare different cooled and noncooled catheter systems in terms of their specific lesion geometry, incidence of impedance rise, and crater and coagulum formation to facilitate appropriate catheter selection for special indications. The study investigated myocardial lesion generation of three cooled catheter systems (7 Fr, 4‐mm tip): two saline irrigation catheters with a showerhead‐type electrode tip (sprinkler) and a porous metal tip and an internally cooled catheter. Noncooled catheters (7 Fr) had a large tip electrode (8 mm) and a standard tip electrode (4 mm). RF energy was delivered on isolated porcine myocardium superfused with heparinized pig blood (37°C) at power settings of 10–40 W. Both irrigated systems were characterized by a large lesion depth ( 8.1 ± 1.6 mm ) and a large lesion diameter ( 13.8 ± 1.6 mm ). In comparison, internally cooled lesions showed a similar lesion depth ( 8.0 ± 1.0 mm ), but a significantly smaller lesion diameter ( 12.3 ± 1.2 mm , P = 0.04 ). Large tip lesions had a similar lesion diameter ( 14.5 ± 1.6 mm ), but a significantly smaller lesion depth ( 6.3 ± 1.0 mm , P = 0.002 ) compared to irrigated lesions. However, lesion volume was not significantly different between the three cooled and the large tip catheter. To induce maximum lesion size, power requirements were three times higher for the irrigation systems and two times higher for the internally cooled and the large tip catheter compared to the standard catheter. Impedance rise was rarest with irrigated and large tip ablation. In case of impedance rise crater formation was a frequent observation (61–93%). Irrigated catheters prevented coagulum formation most effectively. Irrigated rather than internally cooled ablation appears to be most adequate for the induction of deep and long lesions at a low rate of impedance rise and thrombus formation. Large tip ablation may be feasible for the creation of long linear lesions, however, with an increased risk of thrombus formation. (PACE 2003; 26[Pt. I]:1438–1445)Keywords
This publication has 23 references indexed in Scilit:
- Mechanisms for Enlarging Lesion Size During Irrigated Tip Radiofrequency Ablation:. Is There a Virtual Electrode Effect?Journal of Interventional Cardiology, 2004
- Catheter ablation of ventricular tachycardia in patients with structural heart disease using cooled radiofrequency energyJACC, 2000
- Ablation of Ventricular Tachycardia with a Saline‐Cooled Radiofrequency Catheter:Journal of Cardiovascular Electrophysiology, 1999
- ABSTRACT SESSION 13: ABLATION 11: CATHETER ABLATION—ACCESSORY PATHWAYSPacing and Clinical Electrophysiology, 1997
- Radiofrequency Delivery Through a Cooled Catheter Tip Allows the Creation of Larger Endomyocardial Lesions in the Ovine HeartJournal of Cardiovascular Electrophysiology, 1995
- Use of the Saline Infusion Electrode Catheter for Improved Energy Delivery and Increased Lesion Size in Radiofrequency Catheter AblationPacing and Clinical Electrophysiology, 1995
- Myocardial Temperature Response During Radiofrequency Catheter AblationPacing and Clinical Electrophysiology, 1995
- Advanced radiofrequency catheter ablation in canine myocardiumAmerican Heart Journal, 1994
- Treatment of Supraventricular Tachycardia Due to Atrioventricular Nodal Reentry by Radiofrequency Catheter Ablation of Slow-Pathway ConductionNew England Journal of Medicine, 1992
- Tissue Heating During Radiofrequency Catheter Ablation: A Thermodynamic Model and Observations in Isolated Perfused and Superfused Canine Right Ventricular Free WallPacing and Clinical Electrophysiology, 1989