Lumbar Spine Response of Computational Finite Element Models in Multidirectional Spaceflight Landing Conditions
Authors:
- Xin YeXYXin Ye
- Derek A. JonesDJDerek A. Jones
- James P. GaewskyJGJames P. Gaewsky
- Bharath KoyaBKBharath Koya
- Kyle P. McNamaraKMKyle P. McNamara
- Mona SaffarzadehMSMona Saffarzadeh
- Jacob B. PutnamJPJacob B. Putnam
- Jeffrey T. SomersJSJeffrey T. Somers
- F. Scott GayzikFGF. Scott Gayzik
- Joel D. StitzelJSJoel D. Stitzel
- Ashley A. WeaverAWAshley A. Weaver
- 20 January 2020
- journal article
- research article
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 142 (5) , 0510071-05100716
Abstract
The goals of this study are to compare the lumbar spine response variance between the hybrid III, test device for human occupant restraint (THOR), and global human body models consortium simplified 50th percentile (GHBMC M50-OS) finite element models and evaluate the sensitivity of lumbar spine injury metrics to multidirectional acceleration pulses for spaceflight landing conditions. The hybrid III, THOR, and GHBMC models were positioned in a baseline posture within a generic seat with side guards and a five-point restraint system. Thirteen boundary conditions, which were categorized as loading condition variables and environmental variables, were included in the parametric study using a Latin hypercube design of experiments. Each of the three models underwent 455 simulations for a total of 1365 simulations. The hybrid III and THOR models exhibited similar lumbar compression forces. The average lumbar compression force was 45% higher for hybrid III (2.2 ± 1.5 kN) and 51% higher for THOR (2.0 ± 1.6 kN) compared to GHBMC (1.3 ± 0.9 kN). Compared to hybrid III, THOR sustained an average 64% higher lumbar flexion moment and an average 436% higher lumbar extension moment. The GHBMC model sustained much lower bending moments compared to hybrid III and THOR. Regressions revealed that lumbar spine responses were more sensitive to loading condition variables than environmental variables across all models. This study quantified the intermodel lumbar spine response variations and sensitivity between hybrid III, THOR, and GHBMC. Results improve the understanding of lumbar spine response in spaceflight landings.Keywords
This publication has 24 references indexed in Scilit:
- Spacecraft Occupant Protection Requirements: A Review of the Recent ChangesAviation, Space, and Environmental Medicine, 2014
- Has the Incidence of Thoracolumbar Spine Injuries Increased in the United States From 1998 to 2011?Clinical Orthopaedics and Related Research, 2014
- XSEDE: Accelerating Scientific DiscoveryComputing in Science & Engineering, 2014
- Investigation of the THOR Anthropomorphic Test Device for Predicting Occupant Injuries during Spacecraft Launch Aborts and LandingFrontiers in Bioengineering and Biotechnology, 2014
- Lateral Impact Validation of a Geometrically Accurate Full Body Finite Element Model for Blunt Injury PredictionAnnals of Biomedical Engineering, 2012
- A New PMHS Model for Lumbar Spine Injuries During Vertical AccelerationJournal of Biomechanical Engineering, 2011
- NASA Space Flight Human System StandardsProceedings of the Human Factors and Ergonomics Society Annual Meeting, 2007
- What is Intervertebral Disc Degeneration, and What Causes It?Spine, 2006
- Computational biomechanical modelling of the lumbar spine using marching-cubes surface smoothened finite element voxel meshingComputer Methods and Programs in Biomedicine, 2005
- Cortical and Trabecular Bone Mineral Loss From the Spine and Hip in Long-Duration SpaceflightJournal of Bone and Mineral Research, 2004