Field based assessment of a tri-axial accelerometers validity to identify steps and reliability to quantify external load
Open Access
- 12 September 2022
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 13, 942954
Abstract
Background: The monitoring of accelerometry derived load has received increased attention in recent years. However, the ability of such measures to quantify training load during sport-related activities is not well established. Thus, the current study aimed to assess the validity and reliability of tri-axial accelerometers to identify step count and quantify external load during several locomotor conditions including walking, jogging, and running.Method: Thirty physically active college students (height = 176.8 ± 6.1 cm, weight = 82.3 ± 12.8 kg) participated. Acceleration data was collected via two tri-axial accelerometers (Device A and B) sampling at 100 Hz, mounted closely together at the xiphoid process. Each participant completed two trials of straight-line walking, jogging, and running on a 20 m course. Device A was used to assess accelerometer validity to identify step count and the test-retest reliability of the instrument to quantify the external load. Device A and Device B were used to assess inter-device reliability. The reliability of accelerometry-derived metrics Impulse Load (IL) and Magnitude g (MAG) were assessed.Results: The instrument demonstrated a positive predictive value (PPV) ranging between 96.98%–99.41% and an agreement ranging between 93.08%–96.29% for step detection during all conditions. Good test-retest reliability was found with a coefficient of variation (CV) Conclusion: This research indicates that tri-axial accelerometers can be used to identify steps and quantify external load when movement is completed at a range of speeds.Keywords
Funding Information
- Deanship of Scientific Research, King Faisal University ([Project No. GRANT493])
This publication has 35 references indexed in Scilit:
- Validity of using tri-axial accelerometers to measure human movement—Part I: Posture and movement detectionMedical Engineering & Physics, 2013
- Training Adaptation and Heart Rate Variability in Elite Endurance Athletes: Opening the Door to Effective MonitoringSports Medicine, 2013
- Global Positioning Systems (GPS) and Microtechnology Sensors in Team Sports: A Systematic ReviewSports Medicine, 2013
- The use of near-infrared spectroscopy in understanding skeletal muscle physiology: recent developmentsPhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2011
- 3D Measurement of Forearm and Upper Arm during Throwing Motion using Body Mounted SensorJournal of Advanced Mechanical Design, Systems, and Manufacturing, 2010
- Detection of walking periods and number of steps in older adults and patients with Parkinson's disease: accuracy of a pedometer and an accelerometry-based methodAge and Ageing, 2008
- The validation of a novel activity monitor in the measurement of posture and motion during everyday activitiesBritish Journal of Sports Medicine, 2006
- Gait Assessment in Parkinson's Disease: Toward an Ambulatory System for Long-Term MonitoringIEEE Transactions on Biomedical Engineering, 2004
- Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports MedicineSports Medicine, 1998
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986