Magnet eddy-current losses in external rotor permanent magnet generator
- 1 October 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1068-1071
Abstract
This paper studies the permanent magnet eddy-current losses in an external rotor permanent magnet generator (PMG) used in diesel generator (DG) set application. An 18 stator slot 16 rotor pole PMG was designed and analyzed with surface-mounted radial magnets in exterior rotor configuration with NdFeB as the hard magnetic material. Permanent magnet (PM) segmentation technique was utilized for magnet eddy-current loss reduction i.e. the PMs were segmented circumferentially into two magnets per pole. Both the models i.e. with one magnet per pole and with two magnets per pole, were analyzed, fabricated and tested for performance. It is observed that there is considerable reduction in magnet eddy-current losses with two magnets per pole as the rotor magnets.Keywords
This publication has 8 references indexed in Scilit:
- Analytical calculation of rotor magnet eddy-current losses for high speed IPMSM2010
- Permanent magnet loss reduction in PM-machines using analytical and FEM calculation2010
- Modeling Magnet Length In 2-D Finite-Element Analysis of Electric MachinesIEEE Transactions on Magnetics, 2009
- Losses in High Speed Permanent Magnet Machines Used in Microturbine ApplicationsJournal of Engineering for Gas Turbines and Power, 2008
- Effect of Axial Segmentation of Permanent Magnets on Rotor Loss in Modular Permanent-Magnet Brushless MachinesIEEE Transactions on Industry Applications, 2007
- Eddy-Current Losses in the Solid Back-Iron of PM Machines for different Concentrated Fractional Pitch Windings2007
- A study on eddy-current losses in rotors of surface permanent-magnet synchronous machinesIEEE Transactions on Industry Applications, 2006
- Rotor loss in permanent-magnet brushless AC machinesIEEE Transactions on Industry Applications, 2000