Airborne transmission between room occupants during short‐term events: Measurement and evaluation
- 13 April 2019
- journal article
- research article
- Published by Wiley in Indoor Air
- Vol. 29 (4) , 563-576
Abstract
This study experimentally examines and compares the dynamics and short‐term events of airborne cross infection in a full‐scale room ventilated by stratum, mixing and displacement air distributions. Two breathing thermal manikins were employed to simulate a standing infected person and a standing exposed person. Four influential factors were examined, including separation distance between manikins, air change per hour, positioning of the two manikins and air distribution. Tracer gas technique was used to simulate the exhaled droplet nuclei from the infected person and fast tracer gas concentration meters (FCM41) were used to monitor the concentrations. Real‐time and average exposure indices were proposed to evaluate the dynamics of airborne exposure. The time‐averaged exposure index depends on the duration of exposure time and can be considerably different during short‐term events and under steady‐state conditions. The exposure risk during short‐term events may not always decrease with increasing separation distance. It changes over time and may not always increase with time. These findings imply that the control measures formulated on the basis of steady‐state conditions are not necessarily appropriate for short‐term events.Keywords
This publication has 38 references indexed in Scilit:
- Performance evaluation and design guidelines for stratum ventilationBuilding and Environment, 2011
- An experimental study quantifying pulmonary ventilation on inhalation of aerosol under steady and episodic emissionJournal of Hazardous Materials, 2011
- Removal of exhaled particles by ventilation and deposition in a multibed airborne infection isolation roomIndoor Air, 2010
- Personalized ventilation as a control measure for airborne transmissible disease spreadJournal of The Royal Society Interface, 2009
- Transport of particulate and gaseous pollutants in the vicinity of a human bodyBuilding and Environment, 2009
- Modeling particle dispersion and deposition in indoor environmentsAtmospheric Environment, 2007
- Measurement and prediction of indoor air quality using a breathing thermal manikinIndoor Air, 2007
- Study on transport characteristics of saliva droplets produced by coughing in a calm indoor environmentBuilding and Environment, 2006
- Indoor particle dynamicsIndoor Air, 2004
- Peer Reviewed: Defining Intake FractionEnvironmental Science & Technology, 2002