Tear sample collection using cellulose acetate absorbent filters
- 29 October 2008
- journal article
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 28 (6) , 577-583
Abstract
Purpose: To assess the use of cellulose acetate filter rods as a technique for tear collection. Method: The cellulose acetate rod (CR) was compared with the ‘standard’ glass capillary tube (CT), in a series of experiments, to assess: sample collection by collected volume size; the effect of tear stimulation on total tear protein concentration and major tear protein concentrations; and technique invasiveness. Results: No difference was found in concentrations for total protein, IgA (secretory immunoglobulin A), lactoferrin and lysozyme ( p > 0.05) with no clinically significant increase in serum albumin to show serum leakage. Sample volume was higher for CR ( p < 0.005) and sample volume increased for stimulated collection with CR ( p = 0.001). Dilution effect of a stimulated sample size was reliably shown only with CR ( r = −0.66, p = 0.011). Using bovine albumin standard with CR and CT, a smaller sample volume ( p < 0.001) and a higher protein concentration ( p < 0.001) were extracted with CR. Conclusion: The cellulose rod offers a suitable alternative to the glass CT. It is able to quickly absorb a sample, allowing use for a wide range of sample sizes, while being minimally invasive.Keywords
This publication has 33 references indexed in Scilit:
- Use of Polyurethane Minisponges to Collect Human Tear FluidCornea, 2006
- Lachrymal Determinations: Methods and Updates on Biopharmaceutical and Clinical ApplicationsOphthalmic Research, 2004
- Reflex Tear Ascorbate in Hong Kong Chinese Subjects: Method Comparison and Biological VariationOptometry and Vision Science, 2003
- A Novel Method of Tear CollectionCornea, 1997
- Review of the Tear Break-Up Time and a Closer Look at the Tear Break-Up Time of Hong Kong ChineseOptometry and Vision Science, 1993
- Sampling methods for tear stix testsActa Ophthalmologica, 1992
- Identification of proteins in small tear volumes with and without size exclusion HPLC fractionationCurrent Eye Research, 1988
- Biological variations of lysozyme concentration in the tear fluids of healthy persons.British Journal of Ophthalmology, 1986
- Lactoferrin levels in normal human tears.British Journal of Ophthalmology, 1983
- Studien zur Physiologie und Pathologie der Tränenabsonderung und TränenabfuhrGraefe's Archive for Clinical and Experimental Ophthalmology, 1903