Calibration for a Planar Cable-Driven Parallel Robot
Authors:
- Xuejun JinXJXuejun Jin
- Jinwoo JungJJJinwoo Jung
- Jong Pyo JunJJJong Pyo Jun
- Sukho ParkSPSukho Park
- Jong-Oh ParkJPJong-Oh Park
- Seong Young KoSKSeong Young Ko
- 1 November 2015
- journal article
- Published by Institute of Control, Robotics and Systems in Journal of Institute of Control, Robotics and Systems
- Vol. 21 (11) , 1070-1075
Abstract
Calibration for a Planar Cable-Driven Parallel Robot cable-driven parallel robot;calibration;KS B ISO 9283; This paper proposes a calibration algorithm for a three-degree-of-freedom (DOF) planar cable-driven parallel robot (CDPR). To evaluate the proposed algorithm, we calibrated winches and an optical tracking sensor, measured the end-effector pose using the optical tracking sensor, and calculated the accurate robot configuration using the measurement information. To conduct an accuracy test on the end-effector pose, we followed guidelines fromKeywords
This publication has 3 references indexed in Scilit:
- NIMS-PL: A Cable-Driven Robot With Self-Calibration CapabilitiesIEEE Transactions on Robotics, 2009
- Kinematic calibration of a wire-actuated parallel robotMechanism and Machine Theory, 2007
- The NIST robocraneJournal of Robotic Systems, 1993