Evaluation of the current status of the eye lens radiation exposure in an Interventional Radiology department
Authors:
- Antonia AmatielloAAAntonia Amatiello
- Marco CorreraMCMarco Correra
- Vincenzo StoiaVSVincenzo Stoia
- Vincenzo CercielloVCVincenzo Cerciello
- Vincenzo RocaVRVincenzo Roca
- Filomena LoffredoFLFilomena Loffredo
- Francesco FioreFFFrancesco Fiore
Open Access
- 20 December 2018
- journal article
- Published by Mattioli1885 in La Medicina del Lavoro
- Vol. 109 (6) , 471-477
Abstract
Background: Following recent epidemiological studies, which showed tissue reactions from ionizing radiation at significantly lower doses, the 2013/59 EURATOM Directive of 5th December 2013 lowered the limit on the equivalent dose to the eye lens from 150 mSv to 20 mSv per year. Therefore, as a precautionary measure, it is considered appropriate to perform a timely dose monitoring by using specific dosimeters. Objectives: Analysis of the current state of the eye lens exposures during interventional procedures. The survey aimed at assessing the degree of information available to the exposed workers as regards lowering the dose limit in Interventional Radiology departments of some hospitals in Campania (Southern Italy). Methods: The equivalent dose was assessed, over a period of 90 days, using specific Hp dosimeters(3), placed sideways with regard to prescription eye glasses. The level of awareness of the new dose limit among operators was assessed using a questionnaire. Results: The values of the equivalent dose to the lens of the eye for the I and II Operators were found to be <150 mSv/year but for the I Operator a value of 54 mSv/year was obtained, ie higher than 20 mSv/year, that is the new limit of the equivalent dose according to 2013/59 EURATOM. The initial results of the questionnaire from 52 exposed workers, of which 46 (88%) were from exposure category A and 6 (12%) from category B, showed a low level of information (19%). Conclusions: The results highlight not only the importance of using specific devices for individual protection but also the importance of the level of training and information the exposed medical staff are given concerning the new regulations.Keywords
This publication has 12 references indexed in Scilit:
- A multiple methods approach: radiation associated cataracts and occupational radiation safety practices in interventionalists in South AfricaJournal of Radiological Protection, 2017
- Occupational Exposure of the Eye Lens in Interventional Procedures: How to Assess and Manage Radiation DoseJournal of the American College of Radiology, 2016
- Ionizing radiation induced cataracts: Recent biological and mechanistic developments and perspectives for future researchMutation Research - Reviews in Mutation Research, 2016
- Radiation and cataract risk: Impact of recent epidemiologic studies on ICRP judgmentsMutation Research - Reviews in Mutation Research, 2016
- The influence of operator position, height and body orientation on eye lens dose in interventional radiology and cardiology: Monte Carlo simulations versus realistic clinical measurementsPhysica Medica, 2016
- Influence of dosemeter position for the assessment of eye lens dose during interventional cardiologyRadiation Protection Dosimetry, 2014
- Radiation-associated Lens Opacities in Catheterization Personnel: Results of a Survey and Direct AssessmentsJournal of Vascular and Interventional Radiology, 2013
- Occupational Radiation Protection in Interventional Radiology: A Joint Guideline of the Cardiovascular and Interventional Radiology Society of Europe and the Society of Interventional RadiologyCardioVascular and Interventional Radiology, 2009
- A review of radiology staff doses and dose monitoring requirementsRadiation Protection Dosimetry, 2009