Abstract
Summary: The LMA Supreme TM is a new extraglottic airway device which brings together features of the LMA ProSeal TM , Fastrach TM and Unique TM . We test the hypothesis that ease of insertion, oropharyngeal leak pressure, fibreoptic position and ease of gastric tube placement differ between the LMA ProSeal TM and the LMA Supreme TM in paralysed anesthetised patients. Ninety‐three females aged 19–71 years were studied. Both devices were inserted into each patient in random order. Two attempts were allowed. Digital insertion was used for the first attempt and guided insertion for the second attempt. Oropharyngeal leak pressure and fibreoptic position were determined during cuff inflation from 0 to 40 ml in 10 ml increments. Gastric tube insertion was attempted if there was no gas leak from the drain tube. First attempt and overall insertion success were similar (LMA ProSeal TM , 92% and 100%; LMA Supreme TM 95% and 100%). Guided insertion was always successful following failed digital insertion. Oropharyngeal leak pressure was 4–8 ml higher for the LMA ProSeal TM over the inflation range (p < 0.001). Intracuff pressure was 16–35 cm higher for the LMA ProSeal TM when the cuff volume was 20–40 ml (p < 0.001). There was an increase in oropharyngeal leak pressure with increasing cuff volume from 10 to 30 ml for both devices, but no change from 0 to 10 ml and 30–40 ml. There were no differences in the fibreoptic position of the airway or drain tube. The first attempt and overall insertion success for the gastric tube was similar (LMA ProSeal TM 91% and 100%; LMA Supreme TM 92% and 100%). We conclude that ease of insertion, gastric tube placement and fibreoptic position are similar for the LMA ProSeal TM and LMA Supreme TM in paralysed, anaesthetised females, but oropharyngeal leak pressure and intracuff pressure are higher for the LMA ProSeal TM .Keywords
This publication has 16 references indexed in Scilit:
- The LMA Supreme TM – a pilot studyAnaesthesia, 2008
- A Comparison of the Laryngeal Mask Airway ProSeal™ and the Laryngeal Tube Airway in Paralyzed Anesthetized Adult Patients Undergoing Pressure-Controlled VentilationAnesthesia & Analgesia, 2002
- A Comparison of the Laryngeal Mask Airway ProSeal™ and the Laryngeal Tube Airway in Paralyzed Anesthetized Adult Patients Undergoing Pressure-Controlled VentilationAnesthesia & Analgesia, 2002
- Reliability of epigastric auscultation to detect gastric insufflationBritish Journal of Anaesthesia, 2002
- Positive Pressure Ventilation with the ProSeal Versus Classic Laryngeal Mask Airway: A Randomized, Crossover Study of Healthy Female PatientsAnesthesia & Analgesia, 2001
- Routine use of the intubating laryngeal mask airway results in increased upper airway morbidityCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2001
- The LMA ‘ProSeal’—a laryngeal mask with an oesophageal ventBritish Journal of Anaesthesia, 2000
- Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patientsBritish Journal of Anaesthesia, 1999
- A Comparison of the Disposable Versus the Reusable Laryngeal Mask Airway in Paralyzed Adult PatientsAnesthesia & Analgesia, 1998
- Introduction to biostatistics: Part 5, statistical inference techniques for hypothesis testing with nonparametric dataAnnals of Emergency Medicine, 1990