Pure Component Selectivity Analysis of Multivariate Calibration Models from Near-Infrared Spectra
Authors:
- 27 March 2004
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (9) , 2583-2590
Abstract
A novel procedure is proposed as a method to characterize the chemical basis of selectivity for multivariate calibration models. This procedure involves submitting pure component spectra of both the target analyte and suspected interferences to the calibration model in question. The resulting model output is analyzed and interpreted in terms of the relative contribution of each component to the predicted analyte concentration. The utility of this method is illustrated by an analysis of calibration models for glucose, sucrose, and maltose. Near-infrared spectra are collected over the 5000-4000-cm(-)(1) spectral range for a set of ternary mixtures of these sugars. Partial least-squares (PLS) calibration models are generated for each component, and these models provide selective responses for the targeted analytes with standard errors of prediction ranging from 0.2 to 0.7 mM over the concentration range of 0.5-50 mM. The concept of the proposed pure component selectivity analysis is illustrated with these models. Results indicate that the net analyte signal is solely responsible for the selectivity of each individual model. Despite strong spectral overlap for these simple carbohydrates, calibration models based on the PLS algorithm provide sufficient selectivity to distinguish these commonly used sugars. The proposed procedure demonstrates conclusively that no component of the sucrose or maltose spectrum contributes to the selective measurement of glucose. Analogous conclusions are possible for the sucrose and maltose calibration models.Keywords
This publication has 17 references indexed in Scilit:
- Improved calculation of the net analyte signal in inverse multivariate calibrationJournal of Chemometrics, 2001
- Introduction to multivariate calibration in analytical chemistryThe Analyst, 2000
- Temperature-Insensitive Near-Infrared Method for Determination of Protein Concentration during Protein Crystal GrowthAnalytical Chemistry, 2000
- Evaluation of Data Pretreatment and Model Building Methods for the Determination of Glucose from Near-Infrared Single-Beam SpectraApplied Spectroscopy, 1999
- Measurement of Glucose in Water with First-Overtone Near-Infrared SpectraApplied Spectroscopy, 1998
- Adaptive Calibration Scheme for Quantification of Nutrients and Byproducts in Insect Cell Bioreactors by Near-Infrared SpectroscopyBiotechnology Progress, 1998
- PLS-NIR determination of total sugar, glucose, fructose and sucrose in aqueous solutions of fruit juicesAnalytica Chimica Acta, 1997
- Feed-forward artificial neural networks: applications to spectroscopyTrAC Trends in Analytical Chemistry, 1997
- Partial least-squares methods for spectral analyses. 2. Application to simulated and glass spectral dataAnalytical Chemistry, 1988
- Error propagation and figures of merit for quantification by solving matrix equationsAnalytical Chemistry, 1986