Advantages of Atmospheric Pressure Chemical Ionization in Gas Chromatography Tandem Mass Spectrometry: Pyrethroid Insecticides as a Case Study
- 30 October 2012
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 84 (22) , 9802-9810
Abstract
Gas chromatography coupled to mass spectrometry (GC/MS) has been extensively applied for determination of volatile, nonpolar, compounds in many applied fields like food safety, environment, or toxicology. The wide majority of methods reported use electron ionization (EI), which may result in extensive fragmentation of analytes compromising selectivity and sensitivity. This might also complicate the application of tandem MS due to lack of specific/abundant precursor ions. Pyrethroids are examples of compounds with this behavior. In this work, the potential of atmospheric pressure chemical ionization (APCI), a softer form of ionization, combined with GC and a triple quadrupole mass analyzer was investigated, taking pyrethroids as a case study and their determination in fruit and vegetables as example application. Ionization and fragmentation behavior of eight pyrethroids (bifenthrin, cyfluthrin, cypermethrin, permethrin, λ-cyhalothrin, fluvalinate, fenvalerate, and deltamethrin) by APCI were studied. The formation of a highly abundant (quasi) molecular ion was the main goal because of the enhanced selectivity when used as precursor ion in tandem MS. The addition of water as a modifier was tested to promote the generation of protonated molecules, resulting in notable improvement of sensitivity and selectivity for most compounds. The excellent detectability (low detection limits (LODs) <20 fg achieved) when using APCI combined with state-of-the-art tandem MS was demonstrated for real samples. Additionally, matrix effects were evaluated in terms of signal enhancement/suppression. Depending on the matrix, different degrees of suppression were observed, on average reducing the signal in matrix to 55% of that in solvent. The results presented in this paper demonstrate the potential of APCI as new source for GC/MS that could be applied to other analytical problems apart from those illustrated in this work.Keywords
This publication has 36 references indexed in Scilit:
- Single solid phase extraction method for the simultaneous analysis of polar and non-polar pesticides in urine samples by gas chromatography and ultra high pressure liquid chromatography coupled to tandem mass spectrometryTalanta, 2011
- Application of the QuEChERS method for the analysis of pyrethrins and pyrethroids in fish tissuesAnalytical and Bioanalytical Chemistry, 2010
- A rapid and sensitive analytical method for the determination of 14 pyrethroids in water samplesJournal of Chromatography A, 2010
- Use and Reuse of SPE Disks for the Determination of Pyrethroids in Water by GC-ECDAnalytical Letters, 2009
- Development of an Analytical Scheme for the Determination of Pyrethroid Pesticides in Composite Diet SamplesJournal of Agricultural and Food Chemistry, 2009
- Application of solid-phase microextraction for determination of pyrethroids in groundwater using liquid chromatography with post-column photochemically induced fluorimetry derivatization and fluorescence detectionJournal of Chromatography A, 2008
- Extraction and Analysis Methods for the Determination of Pyrethroid Insecticides in Surface Water, Sediments and Biological Tissues at Environmentally Relevant ConcentrationsBulletin of Environmental Contamination and Toxicology, 2008
- Development of an analytical method for the determination of the residues of four pyrethroids in meat by GC–ECD and confirmation by GC–MSAnalytical and Bioanalytical Chemistry, 2007
- Identification and quantitation of pyrethroid pesticide residues in vegetables by solid‐phase extraction and liquid chromatography/electrospray ionization ion trap mass spectrometryRapid Communications in Mass Spectrometry, 2007
- Simple, rapid solid‐phase extraction procedure for the determination of ultra‐trace levels of pyrethroids in ground and sea water by liquid chromatography/electrospray ionization mass spectroscopyRapid Communications in Mass Spectrometry, 2006