Various Electrochemical Measurements in a Simulated Corrosion Fatigue Crack

Authors:
  • ECE. A. Charles
    E. A. Charles
  • JCJ. Congleton
    J. Congleton

Abstract
Measurements of potential, current, pH, and chloride ion concentration were made along a simulated corrosion fatigue crack for HY80f (UNS K31820) steel in seawater. The simulated crack yields results comparable with those from real cracks and allows predictions of potential gradients to be made. The results show that movement of the crevice sides to promote pumping does not cause significant solution refreshment within the enclave at frequencies of 0. 1 and 0. 02 Hz, but flow across the mouth does alter the solution chemistry. These results have been strengthened by diffusion experiments in the crevice. No detectable chloride ion concentration gradients were found in the enclave across the potential range examined.