Glucose Microbiosensor Based on MnO2 and Glucose Oxidase Modified Carbon Fiber Microelectrode
Authors:
- 21 October 2004
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 16 (20) , 1711-1716
Abstract
A glucose microbiosensor has been developed using electrochemical codeposition of glucose oxidase (GOx) along with MnO2 as mediator, onto a single carbon fiber microelectrode. A two‐step deposition of only MnO2 initially and then of MnO2 in the presence of GOx has been introduced to ensure appropriate activity of the mediator. Several parameters such as deposition potential and time, concentration levels etc. have been characterized and optimized. A thin Nafion film was applied as an immobilization/encapsulation and interference‐free protective layer. The proposed microbiosensor was employed as an amperometric glucose detector at pH 7.5 at an operating potential of +0.58 V (vs. Ag/AgCl). The microbiosensor is characterized by a well‐reproducible amperometric response, linear signal‐to‐glucose concentration range from 1.5 mmol L−1 to 15 mmol L−1, and a limit of detection (S/N=3) of 0.8 mmol L−1. The microbiosensor exhibits good stability over more than ten hours of continuous measurement.Keywords
This publication has 25 references indexed in Scilit:
- Analytical Electochemistry2000
- Cobalt and Copper Hexacyanoferrate Modified Carbon Fiber Microelectrode as an All-Solid Potentiometric Microsensor for HydrazineElectroanalysis, 2000
- Electroanalysis and BiosensorsAnalytical Chemistry, 1999
- Amperometric biosensors for clinical and therapeutic drug monitoring: a reviewJournal of Pharmaceutical and Biomedical Analysis, 1999
- Chemical SensorsAnalytical Chemistry, 1998
- Poly(tetrafluoroethylene) Film Housing of Carbon Fibers Using Capillary-Pull Technology for One-Stage Fabrication of Carbon Disk Ultramicroelectrodes and Their CharacterizationAnalytical Chemistry, 1998
- Important Features of Blood Glucose MetersJournal of the American Pharmaceutical Association, 1998
- Over-oxidized polypyrrole-modified carbon fibre ultramicroelectrode with an integrated silver/silver chloride reference electrode for the selective voltammetric measurement of dopamine in extremely small sample volumesThe Analyst, 1996
- Past, present and future contributions of microelectrodes to analytical studies employing voltammetric detection. A reviewThe Analyst, 1994
- ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERYAnnals of the New York Academy of Sciences, 1962