Fast Comprehensive Two-Dimensional Gas Chromatography with Cryogenic Modulation
- 15 May 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (12) , 4448-4454
Abstract
The fast separation of a mixture of 29 compounds by using comprehensive two-dimensional gas chromatography is reported. Capillary column sets with shorter lengths and smaller inner diameter in both the first and second dimensions have been tested, for both fast chiral and achiral separations. Fast chiral separations, which included enantiomer separations of limonene, linalool, citronellol, and α-isomethylionone, were achieved within 23 min, which corresponds to ∼2-fold faster than analyses under conditions previously considered as normal. Fast achiral separations, which do not have the restriction of requiring a minimum quality of chiral resolution, were obtained within 5 min, which is markedly faster than separations on the normal column set under conditions more commonly employed. The achiral fast GC×GC method used a 5 m × 0.1 mm i.d. first dimension column, interfaced to a 0.3 m × 0.05 mm i.d. second column, with temperature program rate of 35 °C.min-1; a modulation period of 1 s was employed. Peak widths at baseline on the first column were a little over 1 s, while modulated peak widths at half-height recorded with a flame ionization detector operating at 200 Hz were ∼30 ms. The benefits and limitations of GC×GC for fast chiral and achiral separations are reported and discussed.Keywords
This publication has 19 references indexed in Scilit:
- Modulation Ratio in Comprehensive Two-dimensional Gas ChromatographyAnalytical Chemistry, 2006
- Fast GC×GC with Short Primary ColumnsAnalytical Chemistry, 2006
- The evolution of comprehensive two‐dimensional gas chromatography (GC×GC)Journal of Separation Science, 2004
- Quantitation of suspected allergens in fragrancesJournal of Chromatography A, 2004
- Practical fast gas chromatography: methods, instrumentation and applicationsTrAC Trends in Analytical Chemistry, 2002
- Application of comprehensive two-dimensional gas chromatography (GC×GC) to the enantioselective analysis of essential oilsJournal of Separation Science, 2001
- Cryogenic solute manipulation in gas chromatography – the longitudinal modulation approachTrAC Trends in Analytical Chemistry, 1999
- Method Translation and Retention Time Locking in Partition GCAnalytical Chemistry, 1998
- Comprehensive Two-Dimensional High-Speed Gas Chromatography with Chemometric AnalysisAnalytical Chemistry, 1998
- Longitudinally Modulated Cryogenic System. A Generally Applicable Approach to Solute Trapping and Mobilization in Gas ChromatographyAnalytical Chemistry, 1997