Abstract
Background: Recently, high-sensitive troponin (hsTrop) assays consistent with professional societies' recommendations became available. We aimed to summarize the evidence on the diagnostic accuracy of hsTrop on presentation. Methods: We searched electronic databases for studies evaluating the diagnostic accuracy of hsTrop in suspected acute coronary syndrome (ACS) patients. Random effect meta-analyses and meta-regression were performed. Primary and secondary analyses were restricted to studies using conventional Trop and hsTrop in the reference standard, respectively. Results: Fifteen studies with a total of 8,628 patients met the inclusion criteria for the primary analysis. hsTrop T (Hoffman-La Roche Ltd) and hsTrop I (Siemens) had sensitivities of 0.89 (95% confidence interval [CI]: 0.86–0.91) and 0.90 (95% CI: 0.87–0.92) and specificities of 0.79 (95% CI: 0.77–0.80) and 0.89 (95% CI: 0.87–0.90), respectively. There was no statistically significant difference in the area under the curve between hsTrop (95% CI: 0.920) and conventional Trop (95% CI: 0.929) at the 99th percentile (P=0.62). hsTrop at the level of detection had a sensitivity of 0.97 (95% CI: 0.96–0.98) and a specificity of 0.41 (95% CI: 0.40–0.42). The studies using a cut-off at coefficient of variance P=0.02). Five studies were included in the secondary analysis; hsTrop T (Hoffman-La Roche Ltd) had a sensitivity of 0.91 (95% CI: 0.89–0.93) and a specificity of 0.67 (95% CI: 0.63–0.70). There was significant heterogeneity among the studies. Conclusion: hsTrop have excellent diagnostic accuracy for myocardial infarction on presentation, but may not outperform conventional Trop assays. The variation among the studies can be explained, in part, by the cut-off used for conventional Trop assays.Keywords
This publication has 37 references indexed in Scilit:
- Diagnostic and prognostic utility of early measurement with high-sensitivity troponin T assay in patients presenting with chest painCanadian Medical Association Journal, 2012
- Serial Changes in Highly Sensitive Troponin I Assay and Early Diagnosis of Myocardial InfarctionJAMA, 2011
- Combined Testing of High-Sensitivity Troponin T and Copeptin on Presentation at Prespecified Cutoffs Improves Rapid Rule-Out of Non–ST-Segment Elevation Myocardial InfarctionClinical Chemistry, 2011
- Combined determination of highly sensitive troponin T and copeptin for early exclusion of acute myocardial infarction: first experience in an emergency department of a general hospitalVascular Health and Risk Management, 2011
- Diagnostic Performance of High-Sensitivity Troponin T, Myeloperoxidase, and Pregnancy-Associated Plasma Protein A Assays for Triage of Patients with Acute Myocardial InfarctionAnnals of Laboratory Medicine, 2011
- High-sensitivity versus conventional troponin in the emergency department for the diagnosis of acute myocardial infarctionCritical Care, 2011
- Diagnostic value of high sensitive troponin T in chest pain patients with no persistent ST-elevationsScandinavian Cardiovascular Journal, 2011
- Prognostic value of sensitive troponin T in patients with stable and unstable angina and undetectable conventional troponinAmerican Heart Journal, 2011
- Sensitive Troponin I Assay in Early Diagnosis of Acute Myocardial InfarctionNew England Journal of Medicine, 2009
- Prognostic Value of Very Low Plasma Concentrations of Troponin T in Patients With Stable Chronic Heart FailureCirculation, 2007