Observer reliability in evaluating pedicle screw placement using computed tomography
Open Access
- 12 September 2006
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 31 (4) , 531-536
Abstract
Pedicle screw insertion in spinal surgery is a demanding technique with potential risks to neurological structures, for example, within the spinal canal. Assessing screw placement in clinical practice has been performed using plain radiographs and/or mainly axial computed tomography (CT) images. Screw placement using CT image reconstructions in multiple planes has been described, but its reliability has yet to be studied. This study aimed at addressing the clinical issue of interobserver and intraobserver reliability in the use of axial and coronal CT images for the assessment of pedicle screw placement. Fifty nine pedicle screws were studied by two experienced radiologists on two separate occasions. Screw placement was classified as “in”, “out” or “questionable”. On average, 88% and 92% of the screws were classified as “in” by the first and second radiologist, respectively. Intraobserver agreement strength was almost perfect for both observers using either axial or coronal images. Interobserver agreement strength was almost perfect (axial) and substantial (coronal) in the first reading and substantial (axial, coronal) in the second reading. Assessing screw placement in more than one CT imaging plane is not only useful but reliable. Routine use may enhance reporting quality of screw placement by surgeons and radiologists.Keywords
This publication has 31 references indexed in Scilit:
- The Accuracy of Computed Tomography in Assessing Cervical Pedicle Screw PlacementSpine, 2003
- Fluoroscopically Assisted Pedicle Screw Fixation for Thoracic and Thoracolumbar InjuriesSpine, 2003
- Stereotactic Navigation for Placement of Pedicle Screws in the Thoracic SpineNeurosurgery, 2001
- Segmental pedicle screw instrumentation in idiopathic thoracolumbar and lumbar scoliosisEuropean Spine Journal, 2000
- The placement of lumbar pedicle screws using computerised stereotactic guidanceThe Journal of Bone and Joint Surgery. British volume, 1999
- Evaluation of Pedicle Screw Position in Thoracic and Lumbar Spine Fixation Using Plain Radiographs and Computed TomographySpine, 1999
- Accuracy of pedicle screw insertion: A prospective CT study in 30 low back patientsEuropean Spine Journal, 1997
- Accuracy of Computer-Assisted Pedicle Screw PlacementSpine, 1997
- Accuracy of Pedicle Screw Placement in Lumbar VertebraeSpine, 1996
- Accuracy of Pedicle Screw Placement in Lumbar Fusions by Plain Radiographs and Computed TomographySpine, 1995