Abstract
Background: Dexmedetomidine is a sedative and analgesic increasingly used in children supported with extracorporeal membrane oxygenation (ECMO). No data is available to describe the pharmacokinetics (PK) of dexmedetomidine in this population. Methods: We performed a single-center prospective PK study. Children Results: Eight children contributed 30 PK samples. None of the PK models evaluated predicted the concentrations with acceptable precision and bias. Four of the six evaluated models overpredicted the concentrations. The addition of a correction factor on clearance improved models' fit. Two of the evaluated models were not applicable to our whole population age range because of their structure. Conclusion: Most of the evaluated PK models overpredicted the concentrations, potentially indicating increased clearance on ECMO. Population PK models applicable to a broad spectrum of ages and pathologies are more practical in pediatric critical care settings but challenging to develop.

This publication has 38 references indexed in Scilit: