Detection of Plasmodium vivax and Plasmodium falciparum using colorimetric loop-mediated isothermal amplification from dried blood spots collected in active and passive malaria surveillance in the Peruvian Amazon
Open Access
- 13 October 2026
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS Neglected Tropical Diseases
- Vol. 20 (10) , e0014366
Abstract
Background: As malaria transmission declines in regions approaching elimination, highly sensitive diagnostic tools are needed to detect low-density infections, particularly in active and passive surveillance settings. Loop-mediated isothermal amplification (LAMP) is a promising molecular alternative to conventional diagnostics. This study evaluated the performance of a colorimetric LAMP (cLAMP) assay for detecting Plasmodium vivax and Plasmodium falciparum from dried blood spots (DBS) in the Peruvian Amazon. Methodology/Principal findings: The cLAMP assay was applied to DNA extracted from DBS collected through active case detection (ACD; n = 574) and passive case detection (PCD; n = 431). Two extraction methods were compared: mini spin column (MSC DNA) and a boil-and-spin (BS DNA) method. Diagnostic performance was evaluated against microscopy and real-time quantitative PCR (qPCR). In ACD samples, qPCR identified 125 malaria-positive cases (117 P. vivax , 8 P. falciparum ). Microscopy showed a sensitivity of 57.6%, compared with 63.2% for cLAMP using BS DNA and 82.4% using MSC DNA. In PCD samples, qPCR detected 140 positives (129 P. vivax , 9 P. falciparum, and 2 mixed infections). Microscopy sensitivity was 72.9%, while cLAMP reached 77.1% with BS DNA and 82.1% with MSC DNA. Specificity remained high (> 99.0%) across methods. Conclusions/Significance: cLAMP improved the detection of malaria infections from DBS compared with microscopy when combined with column-based DNA extraction in active surveillance activities. While the boil-and-spin method showed performance comparable to microscopy, column-based extraction substantially increased sensitivity, especially for low-density infections identified through active surveillance. These findings support cLAMP as a practical and sensitive complementary tool for malaria surveillance in low-transmission and elimination settings.Keywords
Funding Information
- VLIRUOS (PE2018TEA470A102)
- VLIRUOS (PE2022TEA518A102)
This publication has 30 references indexed in Scilit:
- Genomic surveillance of malaria parasites in an indigenous community in the Peruvian AmazonScientific Reports, 2024
- An Update on Malaria Rapid Diagnostic TestsCurrent Infectious Disease Reports, 2018
- Rapid and visual Chlamydia trachomatis detection using loop-mediated isothermal amplification and hydroxynaphthol blueLetters in Applied Microbiology, 2016
- Asymptomatic malaria infections: detectability, transmissibility and public health relevanceNature Reviews Microbiology, 2014
- Highly Sensitive Detection of Malaria Parasitemia in a Malaria-Endemic Setting: Performance of a New Loop-Mediated Isothermal Amplification Kit in a Remote Clinic in UgandaThe Journal of Infectious Diseases, 2013
- Mitochondrial DNA Targets Increase Sensitivity of Malaria Detection Using Loop-Mediated Isothermal AmplificationJournal of Clinical Microbiology, 2010
- Submicroscopic Infection inPlasmodium falciparum–Endemic Populations: A Systematic Review and Meta‐AnalysisThe Journal of Infectious Diseases, 2009
- Detection of Four Plasmodium Species in Blood from Humans by 18S rRNA Gene Subunit-Based and Species-Specific Real-Time PCR AssaysJournal of Clinical Microbiology, 2004
- Loop-mediated isothermal amplification of DNANucleic Acids Research, 2000
- Reliability of malaria microscopy in epidemiological studies: results of quality controlTropical Medicine & International Health, 2000