Experimental tissue mimicking human head phantom for estimation of stroke using IC-CF-DMAS algorithm in microwave based imaging system
Open Access
- 10 November 2021
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-14
Abstract
This paper presents the preparation and measurement of tissue-mimicking head phantom and its validation with the iteratively corrected coherence factor delay-multiply-and-sum (IC-CF-DMAS) algorithm for brain stroke detection. The phantom elements are fabricated by using different chemical mixtures that imitate the electrical properties of real head tissues (CSF, dura, gray matter, white matter, and blood/stroke) over the frequency band of 1–4 GHz. The electrical properties are measured using the open-ended dielectric coaxial probe connected to a vector network analyzer. Individual phantom elements are placed step by step in a three-dimensional skull. The IC-CF-DMAS image reconstruction algorithm is later applied to the phantom to evaluate the effectiveness of detecting stroke. The phantom elements are preserved and measured multiple times in a week to validate the overall performance over time. The electrical properties of the developed phantom emulate the similar properties of real head tissue. Moreover, the system can also effectively detect the stroke from the developed phantom. The experimental results demonstrate that the developed tissue-mimicking head phantom is time-stable, and it shows a good agreement with the theoretical results in detecting and reconstructing the stroke images that could be used in investigating as a supplement to the real head tissue.Keywords
This publication has 31 references indexed in Scilit:
- A COTS-Based Microwave Imaging System for Breast-Cancer DetectionIEEE Transactions on Biomedical Circuits and Systems, 2017
- Introduction to Microwave Imaging2017
- A novel 3D-printed head phantom with anatomically realistic geometry and continuously varying skull resistivity distribution for electrical impedance tomographyScientific Reports, 2017
- Multiple-Frequency DBIM-TwIST Algorithm for Microwave Breast ImagingIEEE Transactions on Antennas and Propagation, 2017
- Ror2 signaling regulates Golgi structure and transport through IFT20 for tumor invasivenessScientific Reports, 2017
- Global stroke statisticsInternational Journal of Stroke, 2016
- Sensitivity of the Distorted Born Iterative Method to the Initial Guess in Microwave Breast ImagingIEEE Transactions on Antennas and Propagation, 2015
- Design and Optimization of an Ultra Wideband and Compact Microwave Antenna for Radiometric Monitoring of Brain TemperatureIEEE Transactions on Biomedical Engineering, 2014
- A Fully Passive Wireless Backscattering Neurorecording Microsystem Embedded in Dispersive Human-Head Phantom MediumIEEE Electron Device Letters, 2012
- Experimental Study of a Hybrid Microwave Radiometry—Hyperthermia Apparatus With the Use of an Anatomical Head PhantomIEEE Transactions on Information Technology in Biomedicine, 2012