Investigation of a method to improve VNA calibration in planar dispersive media through adding an asymmetrical reciprocal device
Author:
- 6 September 2005
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 53 (9) , 3007-3013
Abstract
If a passive asymmetrical reciprocal device is used in addition to short open load thru standards in a two-port vector network analyzer calibration, systematic errors in the calibration kit parameters can be reduced dramatically through numerical optimization to minimize asymmetry after correction. The method is described and the quality of correction assessed using simulated data. Measured results are then presented for calibration on a printed circuit board. Encouraging results and practical limitations are discussed.Keywords
This publication has 6 references indexed in Scilit:
- An optimal vector-network-analyzer calibration algorithmIEEE Transactions on Microwave Theory and Techniques, 2003
- Two-port network analyzer calibration using an unknown 'thru'IEEE Microwave and Guided Wave Letters, 1992
- De-embedding and unterminating microwave fixtures with nonlinear least squaresIEEE Transactions on Microwave Theory and Techniques, 1990
- Numerical Recipes, The Art of Scientific ComputingAmerican Journal of Physics, 1987
- Thru-Reflect-Line: An Improved Technique for Calibrating the Dual Six-Port Automatic Network AnalyzerIEEE Transactions on Microwave Theory and Techniques, 1979
- De-Embedding and UnterminatingIEEE Transactions on Microwave Theory and Techniques, 1974