Numerical estimation of various influence factors on a multipoint hydrostatic leveling system
Authors:
Open Access
- 8 June 2017
- conference paper
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 208 (1) , 012046
Abstract
Among various methods that allow controlling quasi-static vertical displacements of structures, the hydrostatic leveling method remains relevant. A multi-point hydrostatic leveling systems allows controlling the vertical displacement field with the required spatial resolution. It is assumed that the liquid level in the each measuring vessel has the same absolute elevation. However, it is influenced by various external factors, which are difficult to eliminate when implementing the method in real constructions. Consequently, it is necessary to assess the influence of these factors and develop methods aimed at their reduction or compensation. A mathematical model, describing the viscous incompressible fluid motion located in a multipoint level with absolutely rigid walls, is presented in the paper. The experiments performed with two point levels of different lengths, as well as analytical estimates of other authors, made it possible to estimate the degree of confidence of the model and the boundaries of applicability. The influence of non-uniform density of a liquid on the liquid level in a 4-point hydrostatic level of different topologies is numerically estimated using the model. An estimation of transient processes in the level, caused by an air pressure surge over one of the measuring vessels is carried out.Keywords
This publication has 10 references indexed in Scilit:
- Numerical estimation of various influence factors on a multipoint hydrostatic leveling systemIOP Conference Series: Materials Science and Engineering, 2017
- Use of the BINP HLS to measure vertical changes in the locations of the building and ground at the PAL-XFELJournal of the Korean Physical Society, 2016
- Application of Feature Recognition to Hydrostatic Leveling SystemsMeasurement Techniques, 2016
- The Hydrostatic Level Method for Continuous Monitoring of Building FoundationsSolid State Phenomena, 2015
- Long base hydrostatic levelSeismic Instruments, 2014
- Hydrostatic level sensors as high precision ground motion instrumentation for Tevatron and other energy frontier acceleratorsJournal of Instrumentation, 2012
- Hydrostatic levelling systems: Measuring at the system limitsJournal of Applied Geodesy, 2010
- Damped oscillation of liquid column in vertical U-tube for Newtonian and non-Newtonian liquidsJournal of Thermal Science, 2007
- Frequency-dependent friction in oscillatory laminar pipe flowInternational Journal of Mechanical Sciences, 1974
- Hydrostatic Leveling SystemsIEEE Transactions on Nuclear Science, 1965