Test-retest reliability and convergent validity of (R)-[ 11 C]PK11195 outcome measures without arterial input function
Preprint
Abstract
Background: The positron emission tomography radioligand (R)-[ 11 C]PK11195 can be used to quantify the expression of translocator protein (TSPO), which is considered a marker for activation of glial cells. TSPO is expressed throughout the brain, and for this reason no true reference region exists. When a radioligand does not have a reference region, an arterial input function (AIF) is usually required in order to quantify binding. However, obtaining an AIF can be difficult as well as uncomfortable for participants. Alternative methods have therefore been proposed with the aim of estimating (R)-[ 11 C]PK11195 binding without arterial measurements, such as standardized uptake values (SUVs), supervised-cluster analysis (SVCA), or the use of a pseudo-reference region. The objective of this study was to evaluate the test-retest reliability and convergent validity of these techniques. Methods: Data from a previously published (R)-[ 11 C]PK11195 test-retest study in six healthy male subjects were reanalysed. Non-displaceable binding potential (BP ND ) was calculated for a set of cortical and subcortical brain regions using the simplified reference tissue model, with either cerebellum as reference region or a reference input derived using SVCA. SUVs were estimated for the time interval of 40-60 minutes. For comparison, total distribution volume (VT), specific distribution volume (V S ) and BP ND were estimated from the two-tissue-compartment model (2TCM) using AIF. Test-retest reliability was then assessed for all outcome measures. Convergent validity was examined by correlating all measures derived without an AIF to those derived using 2TCM. Results: Test-retest reliability for BP ND estimates were poor (80% of all regional ICCsND estimates derived without an AIF were not correlated with V T , V S or BP ND from the 2TCM (all R 2 2 ND estimated using cerebellum or SVCA as reference input showed poor reliability and little to no convergent validity with outcomes derived using an AIF. SUVs showed moderate reliability but no convergent validity with any other outcome. Caution is warranted for interpreting patient-control comparisons employing (R)-[ 11 C]PK11195 outcome measures obtained without an AIF.Keywords
All Related Versions
- Published version: EJNMMI Research, 8 (1), 102.
This publication has 22 references indexed in Scilit:
- Elevated Translocator Protein in Anterior Cingulate in Major Depression and a Role for Inflammation in Suicidal Thinking: A Positron Emission Tomography StudyBiological Psychiatry, 2018
- Comparison of four 11C-labeled PET ligands to quantify translocator protein 18 kDa (TSPO) in human brain: (R)-PK11195, PBR28, DPA-713, and ER176—based on recent publications that measured specific-to-non-displaceable ratiosEJNMMI Research, 2017
- Test–retest reproducibility of [11C]PBR28 binding to TSPO in healthy control subjectsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2015
- Neuroinflammation in Alzheimer's diseaseThe Lancet Neurology, 2015
- Using Bayes to get the most out of non-significant resultsFrontiers in Psychology, 2014
- Widespread and Prolonged Increase in (R)-11C-PK11195 Binding After Traumatic Brain InjuryJournal of Nuclear Medicine, 2011
- Performance of a modified supervised cluster algorithm for extracting reference region input functions from (R)-[11C]PK11195 brain PET studies2008
- Consensus Nomenclature for in vivo Imaging of Reversibly Binding RadioligandsJournal of Cerebral Blood Flow & Metabolism, 2007
- Kinetic evaluation in nonhuman primates of two new PET ligands for peripheral benzodiazepine receptors in brainSynapse, 2007
- Labelling of peripheral-type benzodiazepine binding sites in human brain with [3H]PK 11195: Anatomical and subcellular distributionBrain Research Bulletin, 1987