Dental CT metal artefact reduction based on sequential substitution
Authors:
- 1 March 2011
- journal article
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 40 (3) , 184-190
Abstract
Objective: Metal artefacts can seriously degrade the visual quality and interpretability of dental CT images. Existing image processing algorithms for metal artefact reduction (MAR) are either too computationally expensive to be used in clinical scanners or effective only in correcting mild artefacts. The aim of the present study was to investigate whether it is possible to improve the efficacy of the computationally efficient projection-correction approach to MAR by exploiting the spatial dependency or autocorrelation between adjacent CT slices. Methods: A new projection-correction algorithm [MAR by sequential substitution (MARSS)] was developed based on the idea that the corrupted portions of the projection data can be substituted with the corresponding portions from an unaffected adjacent slice. The performance of MARSS was evaluated relative to the projection-correction method of Watzke and Kalendar using a two-alternative forced choice (2AFC) visual trial involving 20 observers and 20 clinical CT data sets.16 Results: The Cochran Q test revealed no significant difference in the responses across all observers. The data were then pooled and analysed using a one-tailed exact binomial test. This revealed that the proportion of responses in favour of MARSS was significant (P < 2.2 × 10−16). A second Cochran Q test revealed no significant difference in the responses across all images. Conclusions: It is possible to improve the efficacy of projection correction by exploiting spatial autocorrelation. The 2AFC results suggest that the proposed MARSS algorithm outperforms competing computationally efficient algorithms in terms of reducing metal artefacts whilst at the same time preserving/revealing anatomic detail.Keywords
This publication has 14 references indexed in Scilit:
- Metal artifact reduction in CT using tissue-class modeling and adaptive prefilteringMedical Physics, 2006
- Dental CT Imaging as a Screening Tool for Dental Profiling: Advantages and LimitationsJournal of Forensic Sciences, 2006
- A radial adaptive filter for metal artifact reduction2005
- Artifacts in CT: Recognition and AvoidanceRadioGraphics, 2004
- A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced imagesEuropean Radiology, 2004
- Iterative X-ray Cone-Beam Tomography for Metal Artifact Reduction and Local Region ReconstructionMicroscopy and Microanalysis, 1999
- Iterative deblurring for CT metal artifact reductionIEEE Transactions on Medical Imaging, 1996
- Reduction of CT artifacts caused by metallic implants.Radiology, 1987
- Repeated measurements of dichotomous variables: Q and F tests.Psychological Bulletin, 1982
- A simple computational method for reducing streak artifacts in CT imagesComputerized Tomography, 1980