Single breath hold 3D cardiac cine MRI using kat-ARC: preliminary results at 1.5T
- 14 February 2015
- journal article
- research article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 31 (4) , 851-857
Abstract
Validation of a new single breath-hold, three-dimensional, cine balanced steady-state free precession (3D cine bSSFP) cardiac magnetic resonance (CMR) sequence for left ventricular function. CMR examinations were performed on fifteen patients and three healthy volunteers on a clinical 1.5T scanner using a two-dimensional (2D) cine balanced SSFP CMR sequence (2D cine bSSFP) followed by an investigational 3D cine bSSFP pulse sequence acquired within a single breath hold. Left ventricular end diastolic volume (LVEDV), end systolic volume (LVESV), ejection fraction (LVEF), and myocardial mass were independently segmented on a workstation by two experienced radiologists. Blood pool to myocardial contrast was evaluated in consensus using a Likert scale. Bland–Altman analysis was used to compare these quantitative and nominal measurements for the two sequences. The average acquisition time was significantly shorter for the 3D cine bSSFP than for 2D cine bSSFP (0.36 ± 0.03 vs. 8.5 ± 2.3 min) p = 0.0002. Bland–Altman analyses [bias and (limits of agreement)] of the data derived from these two methods revealed that the LVEF 0.9 % (−4.7, 6.4), LVEDV 4.9 ml (−23.0, 32.8), LVESV −0.2 ml (−22.4, 21.9), and myocardial mass −0.4 g (−23.8, 23.0) were not significantly different. There was excellent intraclass correlation for intra-observer variability (0.981, 0.989, 0.997, 0.985) and inter-observer variability (0.903, 0.954, 0.970, 0.842) for LVEF, LVEDV, LVESV, and myocardial mass respectively. 3D cine bSSFP allows for accurate single breath-hold volumetric cine CMR which enables substantial improvements in scanner time efficiency without sacrificing diagnostic accuracy.Keywords
This publication has 15 references indexed in Scilit:
- Single breathhold three-dimensional cardiac cine MRI with whole ventricular coverage and retrospective cardiac gating using kat ARCJournal of Cardiovascular Magnetic Resonance, 2012
- Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique - comparison of an intravascular and extravascular contrast agentJournal of Cardiovascular Magnetic Resonance, 2012
- Single-Breathhold Four-Dimensional Assessment of Left Ventricular Morphological and Functional Parameters by Magnetic Resonance Imaging Using the VAST TechniqueThe Open Cardiovascular Medicine Journal, 2011
- Respiratory and cardiac self‐gated free‐breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisitionMagnetic Resonance in Medicine, 2010
- Rapid assessment of regional and global left ventricular function using three-dimensional k-t BLAST imagingMagnetic Resonance Imaging, 2008
- Measurement of left ventricular dimensions with contrast-enhanced three-dimensional cine imaging facilitated by k-t SENSEJournal of Cardiovascular Magnetic Resonance, 2008
- Evaluation of global cardiac functional parameters using single-breath-hold three-dimensional cine steady-state free precession MR imaging with two types of speed-up techniques: Comparison with two-dimensional cine imagingComputerized Medical Imaging and Graphics, 2008
- Measurement of signal‐to‐noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filtersJournal of Magnetic Resonance Imaging, 2007
- Image reconstruction in SNR units: A general method for SNR measurement†Magnetic Resonance in Medicine, 2005
- Accelerating cardiac cine 3D imaging using k‐t BLASTMagnetic Resonance in Medicine, 2004