Prosthesis Oversizing in Balloon-Expandable Transcatheter Aortic Valve Implantation Is Associated With Contained Rupture of the Aortic Root
- 1 August 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 5 (4) , 540-548
Abstract
Background—: To retrospectively investigate the potential cause of contained rupture of the aortic root in balloon-expandable transcatheter aortic valve implantation (TAVI) by means of pre- and postinterventional multislice computed tomography. Methods and Results—: Seventy-two patients (mean age 82±7 years, mean aortic valve area 0.69±0.19 cm 2 ) underwent balloon-expandable TAVI using the EdwardsSAPIEN Transcatheter Heart Valve (23 mm, n=19; 26 mm, n=50; 29 mm, n=3). Aortic annulus dimensions were quantified by multislice computed tomography–based cross-sectional area assessment and average diameter calculation (CAAD) before and after TAVI. Post-TAVI multislice computed tomography data sets were available in 65 patients; contained aortic root rupture was diagnosed in 3 patients. Pre-TAVI CAAD was 23.1±1.8 mm; post-TAVI CAAD was 22.9±1.3 mm. Median relative change in CAAD pre- and post-TAVI was −0.5% (interquartile range, 3.6%). Relative increase of 5% to 10% was observed in 4 patients (1 with contained rupture), relative increase >10% in 2 patients, both with contained rupture. Mean relative oversizing, calculated as the relative difference in diameter between pre-TAVI CAAD and nominal diameter of the selected prosthesis, was 9.8%±7.8%. Relative oversizing was significantly higher in patients with contained rupture compared with patients without contained rupture (24.6%±5.4% versus 9.1%±6.6%; P <0.001). Relative oversizing ≥20% occurred in 6 patients (3 with contained rupture). Conclusions—: Contained rupture of the aortic root in balloon-expandable TAVI is associated with severe prosthesis oversizing. Multislice computed tomography–based assessment of aortic annulus dimension in conjunction with adapted sizing guidelines may reduce the incidence of severe oversizing.Keywords
This publication has 27 references indexed in Scilit:
- Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantationHeart, 2011
- Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk PatientsNew England Journal of Medicine, 2011
- Preoperative Assessment of Aortic Annulus Dimensions: Comparison of Noninvasive and Intraoperative MeasurementThe Annals of Thoracic Surgery, 2011
- Transapical Aortic Valve Implantation in 194 Patients: Problems, Complications, and SolutionsThe Annals of Thoracic Surgery, 2010
- Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo SurgeryNew England Journal of Medicine, 2010
- Transcatheter aortic valve implantation: first results from a multi-centre real-world registryEuropean Heart Journal, 2010
- Multimodal Assessment of the Aortic Annulus DiameterJACC, 2010
- Determinants of Significant Paravalvular Regurgitation After Transcatheter Aortic Valve ImplantationJACC: Cardiovascular Interventions, 2009
- Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) CoreValve ReValving System: results from the multicentre, expanded evaluation registry 1-year following CE mark approvalEuroIntervention, 2008
- Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI)European Heart Journal, 2008