Non-Circular Shape of Right Ventricular Outflow Tract
Authors:
- 1 September 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 5 (5) , 621-627
Abstract
Background—: The shape of right ventricular outflow tract (RVOT) has been assumed to be circular. The aim of this study was to assess RVOT morphology using 3-dimensional transesophageal echocardiography (3D TEE). Methods and Results—: This prospective study included 114 patients who underwent 3D TEE. Two-dimensional (2D) TEE measured maximum and minimum RVOT diameters (RVOTD max and min) during a cardiac cycle. 3D TEE determined RVOT area (RVOTA) max and min, RVOT fractional area change, and RVOT shape index (RVOTSI; vertical/horizontal RVOTD). Cardiac output (CO) was calculated using 2D TEE, 3D TEE, and a Swan-Ganz catheter in 23 patients. All patients were classified into group 1 (RVOTSI ≤1) or group 2 (RVOTSI >1) based on the RVOT shapes. The mean RVOTSIs were 0.84±0.21(max) and 0.82±0.20 (min). Only 17 patients (14.9%) had circular RVOT (RVOTSI: 0.95–1.05); 82 patients (71.9%) were categorized into group 1 and 32 patients (28.1%) into group 2. 2D TEE, compared with 3D TEE, underestimated RVOTA max and min (both P r =0.83 and 0.53, respectively). Conclusions—: 3D TEE revealed that RVOT geometry was not generally circular but oval with 2 different types. Because of the detailed morphological information of RVOT, 3D TEE could provide more accurate assessment of CO than 2D TEE.Keywords
This publication has 34 references indexed in Scilit:
- Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registryHeart, 2011
- Assessment of pulmonary valve and right ventricular outflow tract with real-time three-dimensional echocardiographyThe International Journal of Cardiovascular Imaging, 2006
- Non-Invasive Cardiac Output Determination by Two-Dimensional Independent Doppler During and After Cardiac SurgeryThe Annals of Thoracic Surgery, 2005
- Echocardiographic automated cardiac output measurement of pulmonary output and quantification of intracardiac shuntInternational Journal of Cardiology, 2005
- Optimal timing for pulmonary valve replacement in adults after tetralogy of Fallot repairThe American Journal of Cardiology, 2005
- The Development of the Embryonic Outflow Tract Provides Novel Insights into Cardiac Differentiation and RemodelingTrends in Cardiovascular Medicine, 2004
- Non-invasive automated assessment of the ratio of pulmonary to systemic flow in patients with atrial septal defects by the colour Doppler velocity profile integration methodHeart, 2002
- Age-associated changes in left ventricular outflow tract geometry in normal subjectsThe American Journal of Cardiology, 1996
- Pulsed Wave Doppler Measurement of Cardiac Output from the Right Ventricular Outflow TractAnesthesia & Analgesia, 1996
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986