A 12-channel flexible receiver coil for accelerated tongue imaging
Open Access
- 16 January 2020
- journal article
- research article
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 33 (4) , 581-590
Abstract
Objective: MRI of the tongue requires acceleration to minimise motion artefacts and to facilitate real-time imaging of swallowing. To accelerate tongue MRI, we designed a dedicated flexible receiver coil. Materials and methods: We designed a flexible 12-channel receiver coil for tongue MRI at 3T and compared it to a conventional head-and-neck coil regarding SNR and g-factor. Furthermore, two accelerated imaging techniques were evaluated using both coils: multiband (MB) diffusion-tensor imaging (DTI) and real-time MRI of swallowing. Results: The flexible coil had significantly higher SNR in the anterior (2.1 times higher, P = 0.002) and posterior (2.0 times higher, P < 0.001) parts of the tongue, while the g-factor was lower at higher acceleration. Unlike for the flexible coil, the apparent diffusion coefficient (P = 0.001) and fractional anisotropy (P = 0.008) deteriorated significantly while using the conventional coil after accelerating DTI with MB. The image quality of real-time MRI of swallowing was significantly better for hyoid elevation (P = 0.029) using the flexible coil. Conclusion: Facilitated by higher SNR and lower g-factor values, our flexible tongue coil allows faster imaging, which was successfully demonstrated in MB DTI and real-time MRI of swallowing.Keywords
Funding Information
- maurits en anna de kock stichting
This publication has 33 references indexed in Scilit:
- Real‐time MRI of speaking at a resolution of 33 ms: Undersampled radial FLASH with nonlinear inverse reconstructionMagnetic Resonance in Medicine, 2012
- Blipped‐controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g‐factor penaltyMagnetic Resonance in Medicine, 2011
- Custom‐fitted 16‐channel bilateral breast coil for bidirectional parallel imagingMagnetic Resonance in Medicine, 2011
- Novel 16‐channel receive coil array for accelerated upper airway MRI at 3 TeslaMagnetic Resonance in Medicine, 2010
- Real‐time MRI at a resolution of 20 msNMR in Biomedicine, 2010
- Image reconstruction by regularized nonlinear inversion—Joint estimation of coil sensitivities and image contentMagnetic Resonance in Medicine, 2008
- A 128‐channel receive‐only cardiac coil for highly accelerated cardiac MRI at 3 TeslaMagnetic Resonance in Medicine, 2008
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007
- Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraintMagnetic Resonance in Medicine, 2007
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999