Simple limit analysis approach for the optimal strengthening of existing masonry towers
- 10 July 2018
- conference paper
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1978 (1) , 450007
Abstract
The paper provides an insight into the seismic strengthening of masonry towers with horizontal and vertical steel rods by means of a limit analysis approach. The kinematic theorem of limit analysis with five pre-assigned failure mechanisms, observed during post-earthquake surveys, has been implemented for different geometries of idealized towers, aimed to cover a wide range of real masonry towers. Different mechanisms can activate as a consequence of the geometric features in combination with masonry mechanical properties. The possible introduction of horizontal and vertical steel rods is investigated in the same way, simply considering in limit analysis computations the contribution of the reinforcement in the internal dissipation. Thanks to the simplicity of the limit analysis approach, large scale Monte Carlo (MC) simulations with several geometries are carried out. Results show that, depending on the geometry of the tower and the mechanical properties of masonry, different mechanisms can be active and therefore the choice of the reinforcement must be done basing on the expected failure mode. Furthermore, it is possible to evaluate the increase in the load carrying capacity of the tower and to observe any change in the active failure mechanism due to the introduction of reinforcement.Keywords
This publication has 16 references indexed in Scilit:
- Homogenization towards a mechanistic Rigid Body and Spring Model (HRBSM) for the non-linear dynamic analysis of 3D masonry structuresMeccanica, 2017
- Causes of damage to industrial brick masonry chimneysEngineering Failure Analysis, 2017
- Comprehensive FE numerical insight into Finale Emilia Castle behavior under 2012 Emilia Romagna seismic sequence: Damage causes and seismic vulnerability mitigation hypothesisEngineering Structures, 2016
- Non-linear dynamic and static analyses on eight historical masonry towers in the North-East of ItalyEngineering Structures, 2016
- Seismic assessment of historical masonry towers by means of simplified approaches and standard FEMConstruction and Building Materials, 2016
- Numerical model upgrading of a historical masonry palace monitored with a wireless sensor networkInternational Journal of Masonry Research and Innovation, 2016
- Comparative seismic vulnerability analysis on ten masonry towers in the coastal Po Valley in ItalyEngineering Structures, 2013
- A multilevel approach for the damage assessment of Historic masonry towersJournal of Cultural Heritage, 2010
- Numerical models for the seismic assessment of an old masonry towerEngineering Structures, 2010
- Leaning towersMeccanica, 1992