Evaluation of different analytical strategies for the quantification of sulfur-containing biomolecules by HPLC-ICP-MS: Application to the characterisation of 34S-labelled yeast
- 9 April 2010
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 25 (7) , 989-997
Abstract
Different analytical strategies, such as Compound Independent Calibration (CIC), post-column Isotope Dilution Analysis (IDA) and post-column Isotope Pattern Deconvolution (IPD) were evaluated for the determination of sulfur-containing biomolecules. CIC graphs were obtained for the sulfur-containing compounds sulfate, cysteine, glutathione and methionine separated by isocratic HPLC using four different ICP-MS instruments. Instruments evaluated included two quadrupole based instruments (XSeries II and HP-4500), with and without a collision cell respectively, one single collector double focusing (Element 2) and one multicollector double focusing (Neptune). When isocratic HPLC separations were employed, CIC using sulfate standards could be applied for the determination of small peptides and amino acids in their native form. When gradient elution HPLC separations were performed, CIC was no longer suitable and enriched stable isotopes (33S) were evaluated to compensate for gradient-derived changes in the sensitivity for sulfur in the ion source. It was observed that post-column IDA using 33S was suitable for the absolute quantification of sulfate, cysteine, glutathione and methionine by HPLC-ICP-MS when gradient elution was performed. Unfortunately, traditional equations used for post-column IDA can no longer be applied when two different sulfur enriched isotopes are employed. In the characterisation of 34S-labelled yeast we will have three different sulfur isotope patterns: natural abundance sulfur impurities, 34S used as “labelling” tracer and 33S used as post-column “quantification” tracer. So, for the characterisation of 34S-labelled yeast we have developed a post-column IPD procedure that allowed us to obtain the “pattern specific molar flow chromatograms” and, hence, to discriminate between “natural abundance” and “34S-enriched” sulfur species in the 34S-labelled yeast.Keywords
This publication has 40 references indexed in Scilit:
- Inductively Coupled Plasma Mass SpectrometryAnalytical Chemistry, 2008
- Heteroatom(isotope)-tagged proteomics via ICP-MS: screening and quantification of proteins and their post-translational modificationsAnalytical and Bioanalytical Chemistry, 2008
- Chemical labels and natural element tags for the quantitative analysis of bio-moleculesJournal of Analytical Atomic Spectrometry, 2008
- The role of sulfur and sulfur isotope dilution analysis in quantitative protein analysisAnalytical and Bioanalytical Chemistry, 2007
- Precolumn Isotope Dilution Analysis in nanoHPLC−ICPMS for Absolute Quantification of Sulfur-Containing PeptidesAnalytical Chemistry, 2007
- Determination of sulfur-containing amino acids by capillary electrophoresis dynamic reaction cell inductively coupled plasma mass spectrometryAnalytica Chimica Acta, 2004
- Determination of sulfur and selected trace elements in metallothionein-like proteins using capillary electrophoresis hyphenated to inductively coupled plasma mass spectrometry with an octopole reaction cellAnalytical and Bioanalytical Chemistry, 2003
- Sulfur as the Key Element for Quantitative Protein Analysis by Capillary Liquid Chromatography Coupled to Element Mass SpectrometryAngewandte Chemie International Edition, 2003
- Hydrolysis of proteins with methanesulfonic acid for improved HPLC-ICP-MS determination of seleno-methionine in yeast and nutsAnalytical and Bioanalytical Chemistry, 2003
- Ion chromatographic separation of sulfur-containing inorganic anions with an ICP–MS as element-specific detectorJournal of Chromatography A, 1999