Study of Linear-Resistance Flowmeters

Authors:

Abstract
A linear or linear-resistance type of flowmeter can consist of a straight piece of pipe with a porous plug, or a resistance element, and a differential gage across the porous plug. In a certain flow range the volume rate of flow through the meter is directly proportional to the pressure drop across the plug. An investigation was made of linear flowmeters with cotton and steel-wool plug elements. The tests covered a range of pipe sizes, plug lengths, and plug specific weights. Typical characteristic curves are presented. A set of dimensionless ratios is proposed for a correlation of all the data for general application.