Development of ELISA for Measurement of Progesterone Employing 17-α-OH-P-HRP as Enzyme Label
Authors:
- 28 March 2009
- journal article
- research article
- Published by Taylor & Francis in Journal of Immunoassay and Immunochemistry
- Vol. 30 (2) , 186-196
Abstract
The present study was aimed to develop a highly specific and sensitive Enzyme Linked Immunosorbent Assay (ELISA) to measure progesterone in human serum using a heterologous combination of immunogen and enzyme conjugate. The antiserum was raised against Progesterone-3-O-carboxymethyloxime bovine serum albumin (P-3-O-CMO-BSA) in New Zealand white rabbits. The enzyme conjugate was prepared by labeling 17-α-hydroxy-progesterone-3-O-carboxymethyloxime (17-α-OH-P-3-O-CMO) with Horseradish Peroxidase (HRP) to form 17-α-OH-P-3-CMO-HRP. A Checkerboard assay was performed to determine the working dilutions of antiserum and enzyme conjugate. Dose-response studies were carried out by incubating 100µL enzyme conjugate along with 50µL of standards in the primary antibody coated wells for 1 hour. The bound enzyme activity was measured colorimetrically using tetramethyl benzidine/hydrogen peroxide (TMB/H2O2) as substrate. The enzyme substrate reaction was terminated with 100µL of 0.5 M H2SO4 after 20 min and the intensity of the color was measured using Tecan ELISA reader at 450 nm. The assay was validated in terms of sensitivity, specificity, precision and recovery. The lowest detection limit of the assay was 0.2 ng/mL. Cross-reaction with analogous steroids pregnenolone and 17-α-OH-P were found to be 6.8 and 6.1%, respectively. For other analogous steroids, it was less than 0.1%. The intra- and inter-assay coefficient of variation ranges from 4.52–7.39% and 4.65–9.55%, respectively. The developed ELISA correlated well with established RIA, with a correlation coefficient of 0.91 (n = 40).Keywords
This publication has 18 references indexed in Scilit:
- Influence of hydrophobic and hydrophilic spacer-containing enzyme conjugates on functional parameters of steroid immunoassayAnalytical Biochemistry, 2008
- Substitution of Carbonate Buffer by Water for IgG Immobilization in Enzyme Linked Immunosorbent AssayJournal of Immunoassay and Immunochemistry, 2003
- Enzyme immunosorbant assay of oestradiol in unextracted plasma using penicillinase as labelClinica Chimica Acta, 1990
- Chemiluminescence Immunoassay for Progesterone in Plasma Incorporating Acridinium Ester Labelled AntigenAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1988
- An enhanced chemiluminescence enzyme immunoassay for serum progesteroneSteroids, 1984
- Specificity of antisera to sex steroids I—the effect of substitution and stereochemistryThe Journal of Steroid Biochemistry and Molecular Biology, 1977
- The influence of heterologous combinations of antiserum and enzyme-labeled estrogen on the characteristics of estrogen enzyme-immunoassaysImmunochemistry, 1975
- Radioimmunoassay of Plasma ProgesteroneThe Journal of Clinical Endocrinology & Metabolism, 1971
- Steroid Production from Plasma Cholesterol. I. Conversion of Plasma Cholesterol to Placental Progesterone in Humans1The Journal of Clinical Endocrinology & Metabolism, 1970
- Some Studies of the Protein-Binding of Steroids and Their Application to the Routine Micro and Ultramicro Measurement of Various Steroids in Body Fluids by Competitive Protein-Binding Radioassay1The Journal of Clinical Endocrinology & Metabolism, 1967