Experimental assessment of rainwater management of a ventilated façade
- 20 July 2017
- journal article
- research article
- Published by SAGE Publications in Journal of Building Physics
- Vol. 42 (1) , 38-67
Abstract
Façades are not watertight systems in which the exterior surface of the cladding plays the role of the water shedding surface; the air space is the drainage plane; the exterior surface of the thermal insulation layer acts as water-resistive barrier, and the interior layer of the inner leaf is supposed to be the air barrier. The degree of watertightness of ventilated façades relies on the characteristics of the materials used, the geometry of the external cladding element, and edge profile of the joints. Hence, in this article, we extrapolate the laboratory testing to develop a holistic approach on the water management of ventilated façades. The laboratory test showed that 50% of the water deposited to the surface of the wall splashes back, 22% creates a runoff film along the exterior surface of the cladding, 27% infiltrates into the cavity behind the cladding, and <1% reaches the inner layer of the wall. Given these results, the moisture load has been determined for a range of wind-driven rain loads and vertical joint configurations. Such information can be used as input to hygrothermal simulations.Keywords
This publication has 10 references indexed in Scilit:
- Watertightness Assessment of Blown-in Retrofit Cavity Wall InsulationEnergy Procedia, 2015
- Design and construction recommendations to improve impermeability in rainscreen walls built with natural stone coveringsConstruction and Building Materials, 2011
- Study of influence of wind pressure and rain conditions in rain screen wallsStructural Survey, 2010
- Maintainability of Facilities2010
- Impact, absorption and evaporation of raindrops on building facadesBuilding and Environment, 2009
- Water entry function of a hardboard siding-clad wood stud wallBuilding and Environment, 2005
- A modified on-site water chamber tester for masonry wallsConstruction and Building Materials, 2001
- Rain Control and Design StrategiesJournal of Thermal Envelope and Building Science, 1999
- Water permeation through cracked single skin masonryBuilding and Environment, 1995
- The prevention of rain penetration through external walls and joints by means of pressure equalizationBuilding and Environment, 1984