Experimental study on the supply air characteristics and thermal comfort of a novel personalized ventilation air terminal device
Authors:
- 1 March 2023
- journal article
- research article
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 32 (6) , 1269-1287
Abstract
Personalized ventilation (PV) has a significant potential for improving thermal comfort, inhaled air quality and energy efficiency. A novel PV air terminal device (ATD) based on the function of bath showers was evaluated to determine discomfort related to thermal sensation, draughts, dry eyes and skin irritation. The supply air characteristics and thermal comfort were analyzed using objective and subjective experiments in an environmental chamber. Thirty college students participated in the subjective experiments. Results showed that the proposed PV ATD could provide uniform distributions of air velocity at the human head and chest. Compared with the conventional round-monitor panel ATD, the proposed PV ATD can provide an improved cooling effect, wherein overall thermal sensation was reduced by 0.56 scale, showing a potential for energy saving. Moreover, the proposed PV ATD could produce a highly uniform distribution of local thermal sensation (LTS). Compared with the conventional PV, the proposed PV ATD could reduce the standard deviation of distribution of LTS by 41.7% and reduce overall thermal discomfort by 45.5%. Fewer sick building syndrome symptoms at a lower supply airflow rate of 6.3 L/s was achieved. Consequently, the proposed PV ATD could improve the comfort performance with the usage of lower supply airflow rates.Keywords
Funding Information
- National Natural Science Foundation of China (51608066)
This publication has 41 references indexed in Scilit:
- The effect of temperature, metabolic rate and dynamic localized airflow on thermal comfortApplied Energy, 2013
- A dynamic air supply device used to produce simulated natural wind in an indoor environmentBuilding and Environment, 2012
- Revisiting an old hypothesis of human thermal perception: alliesthesiaBuilding Research & Information, 2011
- Thermal performance of a personalized ventilation air terminal device at two different turbulence intensitiesBuilding and Environment, 2007
- Human Response to an Individually Controlled MicroenvironmentHVAC&R Research, 2007
- The Acceptable Air Velocity Range for Local Air Movement in The TropicsHVAC&R Research, 2006
- Human Response to Five Designs of Personalized VentilationHVAC&R Research, 2006
- Performance of Personalized Ventilation in Conjunction with Mixing and Displacement VentilationHVAC&R Research, 2006
- Human response to personalized ventilation and mixing ventilationIndoor Air, 2004
- Measurement of acute response to draught in the eyeActa Ophthalmologica, 1987