Characteristics of surgically induced astigmatism after standardized microincisional cataract surgery with a superior limbal incision
- 1 October 2023
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (10) , 1025-1035
Abstract
Purpose: To determine (1) if measurements of surgically induced astigmatism (SIA) as measured by keratometry (K) and total keratometry (TK) differ (2) if SIA affects the magnitude and/or meridian of keratometric astigmatism (3) if SIA evolves over time. Setting: Tertiary care center. Design: Retrospective data analysis. Methods: A swept-source optical coherence tomography biometry dataset (IOLMaster700) consisting of 498 eyes (327 patients) from a tertiary care center was analyzed. For all eyes preoperative and postoperative biometric measurements at 1-month, 3-month, and 6-months postoperative visits were considered for vector analysis of SIAK and SIATK. Results: Centroids in right and left eyes were 0.26 diopters (D) @5 degrees/0.31 D @1 degree for SIAK and 0.27 D @4 degrees/0.34 D @1 degree for SIATK. Centroids for difference vectors K-TK in right and left eyes were 0.02 D @ 176 degrees/0.03 D @6 degrees. The mean SIA magnitudes in right and left eyes were 0.48 ± 0.41 D and 0.50 ± 0.37 D for SIAK and 0.53 ± 0.42 D and 0.54 ± 0.40 D for SIATK. In eyes with ATR astigmatism, an increase in postoperative astigmatism magnitude was more common than a decrease. More than 30% of eyes showed changes in the meridian of more than 15 degrees. Conclusions: Overall, we observed differences in K- and TK-derived SIA, and changes in SIA magnitude over time. For postsurgical interventions, postoperative astigmatism meridian values should be measured to base treatments. Astigmatism magnitude showed a tendency to decrease for steep-meridian incisions and to increase in flat-meridian incisions.Keywords
This publication has 34 references indexed in Scilit:
- The 10,000 Eyes Study: Analysis of Keratometry, Abulafia-Koch regression transformation, and Biometric Eye Parameters Obtained With Swept-Source Optical Coherence TomographyAmerican Journal of Ophthalmology, 2022
- Rückrechnung des Keratometerindex – Welcher Wert wäre bei der Kataraktchirurgie richtig gewesen?Der Ophthalmologe, 2020
- Comparison of refractive outcomes using conventional keratometry or total keratometry for IOL power calculation in cataract surgeryGraefe's Archive for Clinical and Experimental Ophthalmology, 2019
- Fluctuations in corneal curvature limit predictability of intraocular lens power calculationsJournal of Cataract & Refractive Surgery, 2013
- Contribution of posterior corneal astigmatism to total corneal astigmatismJournal of Cataract & Refractive Surgery, 2012
- New method of quantifying corneal topographic astigmatism that corresponds with manifest refractive cylinderJournal of Cataract & Refractive Surgery, 2012
- Comparison of corneal power, corneal astigmatism, and axis location in normal eyes obtained from an autokeratometer and a corneal topographerJournal of Cataract & Refractive Surgery, 2012
- Results of higher power toric intraocular lens implantationJournal of Cataract & Refractive Surgery, 2011
- Effect of uncorrected astigmatism on visionJournal of Cataract & Refractive Surgery, 2011
- Sources of error in intraocular lens power calculationJournal of Cataract & Refractive Surgery, 2008