A large-scale multicentre study of patient skin doses in interventional cardiology: dose–area product action levels and dose reference levels
Authors:
- E BogaertEBE Bogaert
- K BacherKBK Bacher
- K LemmensKLK Lemmens
- M CarlierMCM Carlier
- W DesmetWDW Desmet
- X DE WagterXWX DE Wagter
- D DjianDDD Djian
- C HanetCHC Hanet
- G HeyndrickxGHG Heyndrickx
- V LegrandVLV Legrand
- Y TaeymansYTY Taeymans
- H ThierensHTH Thierens
- 1 April 2009
- journal article
- research article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 82 (976) , 303-312
Abstract
For 318 patients in 8 different Belgian hospitals, the entire skin-dose distribution was mapped using a grid of 70 thermoluminescence dosimeters per patient, allowing an accurate determination of the maximum skin dose (MSD). Dose-area product (DAP) values, exposure parameters and geometry, together with procedure, patient and cardiologist characteristics, were also registered. Procedures were divided into two groups: diagnostic procedures (coronary angiography) and therapeutic procedures (dilatation, stent, combined procedures (e.g. coronary angiography + dilatation + stent)). The mean value of the MSD was 0.310 Gy for diagnostic and 0.699 Gy for therapeutic procedures. The most critical projection for receiving the MSD is the LAO90 (left anterior oblique) geometry. In 3% of cases, the MSD exceeded the 2 Gy dose threshold for deterministic effects. Action levels in terms of DAP values as the basis for a strategy for follow-up of patients for deterministic radiation skin effects were derived from measured MSD and cumulative DAP values. Two DAP action levels are proposed. A first DAP action level of 125 Gy cm(2) corresponding to the dose threshold of 2 Gy would imply an optional radiopathological follow-up depending on the cardiologist's decision. A second DAP action level of 250 Gy cm(2) corresponding to the 3 Gy skin dose would imply a systematic follow-up. Dose reference levels - 71.3 Gy cm(2) for diagnostic and 106.0 Gy cm(2) for therapeutic procedures - were derived from the 75 percentile of the DAP distributions. As a conclusion, we propose that total DAP is registered in patient's record file, as it can serve to improve the follow-up of patients for radiation-induced skin injuries.Keywords
This publication has 22 references indexed in Scilit:
- Radiation Exposure to Patient's Skin During Percutaneous Coronary Intervention for Various Lesions, Including Chronic Total OcclusionCirculation Journal, 2006
- Skin dose alarm levels in cardiac angiography procedures: is a single DAP value sufficient?British Journal of Radiology, 2005
- ACCF/AHA/HRS/SCAI Clinical Competence Statement on Physician Knowledge to Optimize Patient Safety and Image Quality in Fluoroscopically Guided Invasive Cardiovascular ProceduresCirculation, 2005
- Identification of less-irradiating tube angulations in invasive cardiologyJACC, 2004
- Effective techniques for reduction of radiation dosage to patients undergoing invasive cardiac proceduresBritish Journal of Radiology, 2003
- Relationships Between Entrance Skin Dose, Effective Dose and Dose Area Product for Patients in Diagnostic and Interventional Cardiac ProceduresRadiation Protection Dosimetry, 2000
- Patient Dosimetry During Interventional Cardiology ProceduresRadiation Protection Dosimetry, 1998
- Patient dose values in interventional radiologyBritish Journal of Radiology, 1995
- Potential Biological Effects Following High X-ray Dose Interventional ProceduresJournal of Vascular and Interventional Radiology, 1994
- Comparative Robustness of Six Tests in Multivariate Analysis of VarianceJournal of the American Statistical Association, 1974