Device closure of atrial septal defect: medium-term outcome with special reference to complications
Authors:
- 11 July 2011
- journal article
- research article
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 22 (1) , 71-78
Abstract
Background: There are concerns over the outcome of device closure of secundum atrial septal defect with special reference to erosions and aortic regurgitation.Aim: To assess the medium-term outcome of device closure of atrial septal defects with special reference to complications.Methods: A total of 205 patients with secundum atrial septal defects underwent transcatheter closure from October, 1999 to April, 2009. The median age was 18 (1.4–55) years. Amplatzer Septal Occluder was used in all the patients. Medium-term follow-up was available in 176 of 200 (88%) patients.Results: Device closure was successful in 200 out of 205 (98%) patients. The device embolised in four patients and was associated with short inferior caval vein margin (p = 0.003). Balloon sizing in 71 patients (35%) resulted in implantation of a larger device (p = 0.002). Early complications included pericardial effusion, 2:1 heart block, and infective endocarditis (1 patient each). There were eight patients who reported migraine (3.9%). At median follow-up of 5.8 (0.6–10.3) years, complete closure occurred in 197 out of 200 patients. Short superior caval vein margin was associated with a residual shunt (p < 0.001). There were two patients who developed mild aortic regurgitation (1%), which correlated with a device-to-defect ratio of >1.3:1 (p = 0.001). There were no erosions, late embolisation, or thromboembolism. Atrial fibrillation occurred in three adults (1.5%).Conclusions: Device closure of secundum atrial septal defects using Amplatzer Septal Occluder is safe and effective in the medium term. Short inferior caval vein margin correlates with increased risk of embolisation and short superior caval vein margin with a residual shunt. The risk of developing aortic regurgitation is low and correlates with increased device-to-defect ratio.Keywords
This publication has 27 references indexed in Scilit:
- Long-Term Follow Up of Secundum Atrial Septal Defect Closure with the Amplatzer Septal OccluderCongenital Heart Disease, 2010
- Percutaneous Closure of Atrial Septal DefectsCirculation: Cardiovascular Interventions, 2009
- Chronotropic impairment after surgical or percutaneous closure of atrial septal defectCatheterization and Cardiovascular Interventions, 2009
- Unusual Complication With Transcatheter Closure of an Atrial Septal Defect Prevented by Adequate ImagingCirculation, 2008
- Complications in atrial septal defect device closureInteractive CardioVascular and Thoracic Surgery, 2008
- Complications of transcatheter closure of atrial septal defectsHeart, 2005
- Effect of acute changes in load on left ventricular diastolic function during device closure of atrial septal defectsThe American Journal of Cardiology, 2005
- Transcatheter closure as standard treatment for most interatrial defects: experience in 200 patients treated with the Amplatzer ™ Septal OccluderCardiology in the Young, 1999
- Transcatheter Closure of Atrial Communications Using the Amplatzer? Septal OccluderJournal of Interventional Cardiology, 1999
- Early clinical experience with use of the ‘Amplatzer Septal Occluder’ device for atrial septal defectCardiology in the Young, 1998