Comparison of nonself‐tapping tapered implant and self‐tapping hybrid implant in terms of implant stability at initial and second fixation: A prospective randomized clinical trial
Authors:
- 13 October 2020
- journal article
- research article
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 22 (6) , 679-688
Abstract
Background: Various features are provided in dental implants to improve initial fixation.Purpose: To compare the implant stability of the nonself‐tapping tapered implant and self‐tapping hybrid implant over a 3‐month healing period.Materials and methods: A randomized controlled trial was conducted. Patients were randomly divided into tapered and self‐tapping groups. Patients in the tapered group received NobelReplace Tapered (Nobel Biocare, Sweden) implants, while those in the self‐tapping group received NobelSpeedy (Nobel Biocare, Sweden) implants. Implant stability was measured by resonance frequency analysis at surgery and 3 months following implant insertion. Data were analyzed using an independent t‐test.Results: Forty‐three patients (tapered group: 21, self‐tapping group: 22) received a total of 88 implants. Initial stability in the tapered group was significantly higher (mean: 60.14, SD: 12.40) than that in the self‐tapping group (mean: 54.72, SD: 7.92). Implant stability significantly increased 3 months after implantation in the tapered group (mean: 66.61, SD: 9.00) and self‐tapping group (mean: 64.01, SD: 5.78). No significant intergroup difference in implant stability was noted 3 months after surgery.Conclusions: The tapered shape affected initial fixation more than the self‐tapping function. However, during the second fixation, both implants showed good stability, and the difference disappeared.Keywords
This publication has 35 references indexed in Scilit:
- Stability Development of Immediately Loaded Hybrid Self-Tapping Implants Inserted in the Posterior Maxilla: 1-Year Results of a Randomized Controlled TrialJournal of Oral Implantology, 2017
- 10‐year survival rate and the incidence of peri‐implant disease of 374 titanium dental implants with aSLAsurface: a prospective cohort study in 177 fully and partially edentulous patientsClinical Oral Implants Research, 2014
- Retrospective cohort study of 4591 Straumann implants in private practice setting, with up to 10‐year follow‐up. Part 1: multivariate survival analysisClinical Oral Implants Research, 2014
- Posterior maxillary implants inserted with bicortical anchorage and placed in immediate function for partial or complete edentulous rehabilitations. A retrospective clinical study with a median follow-up of 7 yearsOral and Maxillofacial Surgery, 2014
- Role of Clinician's Experience and Implant Design on Implant Stability. An Ex Vivo Study in Artificial Soft BonesClinical Implant Dentistry and Related Research, 2012
- Is the osseointegration of immediately and delayed loaded implants the same?—comparison of the implant stability during a 3‐month healing period in a prospective studyClinical Oral Implants Research, 2009
- The Effects of Superficial Roughness and Design on the Primary Stability of Dental ImplantsClinical Implant Dentistry and Related Research, 2009
- Implant micromotion is related to peak insertion torque and bone densityClinical Oral Implants Research, 2009
- Influence of implant taper on the primary and secondary stability of osseointegrated titanium implantsClinical Oral Implants Research, 2004
- In Vivo Bone Response to Biomechanical Loading at the Bone/Dental-Implant InterfaceAdvances in Dental Research, 1999