A photoelastic study of ligament strain
Authors:
- T. KawadaTKT. Kawada
- 1 September 1998
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Rehabilitation Engineering
- Vol. 6 (3) , 300-308
Abstract
The anterior cruciate ligament (ACL) in the human knee is known to exhibit as large as 10-20% of strain in association with knee flexion, while usual Hookean elastic materials exhibit at most 0.3%. Furthermore the complex ACL in shape deforms in highly variable manners due to the complicated three-dimensional (3-D) movements of the insertions in association with knee flexion. Such large and highly variable deformations of the ACL cannot be adequately quantified by one-dimensional (1-D) and/or localized measurements. In order to measure strains over the entire area of the ACL, the authors employed the photoelastic coating method to analyze stress on the basis of the strains. A specific kind of polyurethane possessing optically high fringe-sensitivity was found to be most suitable for measurement purposes. From the preliminary experiments, it was found that a linear relation with 99% of correlation coefficient between the birefringence order and the strain on the polyurethane film continued up to 45% of strain. This study was done in two steps. In the first step, a study was done using a unique model of a knee joint fabricated in a way which allowed deformation and strain distribution in the model ACL to be directly observed and measured by means of the photoelastic coating method. It was confirmed that the film, having negligible effect on the mechanical properties of some biological soft tissues, closely reflected the strain behavior of the tissue. Thus in the second step, the photoelastic method was employed to measure the strains on an actual ACL during free flexion-extension of the knee. A specially designed apparatus was used to allow a natural motion of the knee. The photoelastic measurements demonstrated the potential utility of the application to measuring strain distributions not only on a model ligament but also on an actual ligament. The measurement of an actual ACL led the following results: the principal strain lines well depicted its fiber directions; a reciprocal function between the anterior and posterior bundles was observed; and there was a zero-strain area on the central and posterior sides near the tibial insertion.Keywords
This publication has 7 references indexed in Scilit:
- Experimental and mathematical methods for representing relative surface elongation of the ACLJournal of Biomechanics, 1995
- Anterior-posterior and rotational displacement of the tibia elicited by quadriceps contractionThe American Journal of Sports Medicine, 1992
- Tensile properties of the human femur-anterior cruciate ligament-tibia complexThe American Journal of Sports Medicine, 1991
- New experimental procedures to evaluate the biomechanical properties of healing canine medial collateral ligamentsJournal of Orthopaedic Research, 1987
- Strain within the anterior cruciate ligament during hamstring and quadriceps activity*The American Journal of Sports Medicine, 1986
- Comparison of material properties in fascicle-bone units from human patellar tendon and knee ligamentsJournal of Biomechanics, 1986
- Anatomy of the Anterior Cruciate LigamentClinical Orthopaedics and Related Research, 1983