Automated estimation of parasitaemia of Plasmodium yoelii-infected mice by digital image analysis of Giemsa-stained thin blood smears
Open Access
- 1 December 2010
- journal article
- research article
- Published by Springer Nature in Malaria Journal
- Vol. 9 (1) , 348
Abstract
Background: Parasitaemia, the percentage of infected erythrocytes, is used to measure progress of experimental Plasmodium infection in infected hosts. The most widely used technique for parasitaemia determination is manual microscopic enumeration of Giemsa-stained blood films. This process is onerous, time consuming and relies on the expertise of the experimenter giving rise to person-to-person variability. Here the development of image-analysis software, named Plasmodium AutoCount, which can automatically generate parasitaemia values from Plasmodium-infected blood smears, is reported. Methods: Giemsa-stained blood smear images were captured with a camera attached to a microscope and analysed using a programme written in the Python programming language. The programme design involved foreground detection, cell and infection detection, and spurious hit filtering. A number of parameters were adjusted by a calibration process using a set of representative images. Another programme, Counting Aid, written in Visual Basic, was developed to aid manual counting when the quality of blood smear preparation is too poor for use with the automated programme. Results: This programme has been validated for use in estimation of parasitemia in mouse infection by Plasmodium yoelii and used to monitor parasitaemia on a daily basis for an entire challenge infection. The parasitaemia values determined by Plasmodium AutoCount were shown to be highly correlated with the results obtained by manual counting, and the discrepancy between automated and manual counting results were comparable to those found among manual counts of different experimenters. Conclusions: Plasmodium AutoCount has proven to be a useful tool for rapid and accurate determination of parasitaemia from infected mouse blood. For greater accuracy when smear quality is poor, Plasmodium AutoCount, can be used in conjunction with Counting Aid.Keywords
This publication has 10 references indexed in Scilit:
- Improving quantitation of malaria parasite burden with digital image analysisTransactions of the Royal Society of Tropical Medicine and Hygiene, 2008
- Investigation of a novel approach to scoring Giemsa-stained malaria-infected thin blood filmsMalaria Journal, 2008
- A novel semi-automatic image processing approach to determine Plasmodium falciparum parasitemia in Giemsa-stained thin blood smearsBMC Cell Biology, 2008
- Development and validation of flow cytometric measurement for parasitaemia using autofluorescence and YOYO-1 in rodent malariaParasitology, 2007
- MalariaCount: An image analysis-based program for the accurate determination of parasitemiaJournal of Microbiological Methods, 2007
- Automated image processing method for the diagnosis and classification of malaria on thin blood smearsMedical & Biological Engineering & Computing, 2006
- Improvement of detection specificity of Plasmodium‐infected murine erythrocytes by flow cytometry using autofluorescence and YOYO‐1Cytometry Part A, 2005
- Immunization with a Combination of Merozoite Surface Proteins 4/5 and 1 Enhances Protection against Lethal Challenge withPlasmodium yoeliiInfection and Immunity, 2002
- Optimisation of flow cytometric measurement of parasitaemia in plasmodium-infected miceInternational Journal for Parasitology, 2000
- Finding circles by an array of accumulatorsCommunications of the ACM, 1975