Deep Learning–Based Automated Echocardiographic Quantification of Left Ventricular Ejection Fraction: A Point-of-Care Solution
- 1 June 2021
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Imaging
- Vol. 14 (6) , 528-537
Abstract
Background: We have recently tested an automated machine-learning algorithm that quantifies left ventricular (LV) ejection fraction (EF) from guidelines-recommended apical views. However, in the point-of-care (POC) setting, apical 2-chamber views are often difficult to obtain, limiting the usefulness of this approach. Since most POC physicians often rely on visual assessment of apical 4-chamber and parasternal long-axis views, our algorithm was adapted to use either one of these 3 views or any combination. This study aimed to (1) test the accuracy of these automated estimates; (2) determine whether they could be used to accurately classify LV function. Methods: Reference EF was obtained using conventional biplane measurements by experienced echocardiographers. In protocol 1, we used echocardiographic images from 166 clinical examinations. Both automated and reference EF values were used to categorize LV function as hyperdynamic (EF>73%), normal (53%–73%), mildly-to-moderately (30%–52%), or severely reduced (<30%). Additionally, LV function was visually estimated for each view by 10 experienced physicians. Accuracy of the detection of reduced LV function (EF<53%) by the automated classification and physicians’ interpretation was assessed against the reference classification. In protocol 2, we tested the new machine-learning algorithm in the POC setting on images acquired by nurses using a portable imaging system. Results: Protocol 1: the agreement with the reference EF values was good (intraclass correlation, 0.86–0.95), with biases <2%. Machine-learning classification of LV function showed similar accuracy to that by physicians in most views, with only 10% to 15% cases where it was less accurate. Protocol 2: the agreement with the reference values was excellent (intraclass correlation=0.84) with a minimal bias of 2.5±6.4%. Conclusions: The new machine-learning algorithm allows accurate automated evaluation of LV function from echocardiographic views commonly used in the POC setting. This approach will enable more POC personnel to accurately assess LV function.Keywords
This publication has 15 references indexed in Scilit:
- Fully Automated Echocardiogram Interpretation in Clinical PracticeCirculation, 2018
- Reduced variability of visual left ventricular ejection fraction assessment with reference images: The Japanese Association of Young Echocardiography Fellows multicenter studyJournal of Cardiology, 2018
- An Overview and Evaluation of Recent Machine Learning Imputation Methods Using Cardiac Imaging DataData, 2017
- Difficulties encountered by physicians in interpreting focused echocardiography using a pocket ultrasound machine in prehospital emergenciesEuropean Journal of Emergency Medicine, 2015
- Recommendations for Cardiac Chamber Quantification by Echocardiography in Adults: An Update from the American Society of Echocardiography and the European Association of Cardiovascular ImagingJournal of the American Society of Echocardiography, 2015
- Improved Interobserver Variability and Accuracy of Echocardiographic Visual Left Ventricular Ejection Fraction Assessment through a Self-Directed Learning Program Using Cardiac Magnetic Resonance ImagesJournal of the American Society of Echocardiography, 2013
- Real-Time 3-Dimensional Echocardiographic Quantification of Left Ventricular VolumesJACC: Cardiovascular Imaging, 2008
- Standardized cardiovascular magnetic resonance imaging (CMR) protocols, society for cardiovascular magnetic resonance: board of trustees task force on standardized protocolsJournal of Cardiovascular Magnetic Resonance, 2008
- A visual approach for the accurate determination of echocardiographic left ventricular ejection fraction by medical studentsJournal of the American Society of Echocardiography, 2003
- Determination of left ventricular ejection fraction by visual estimation during real-time two-dimensional echocardiographyAmerican Heart Journal, 1982