Ultrastable gold substrates for electron cryomicroscopy
Top Cited Papers
- 12 December 2014
- journal article
- other
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 346 (6215) , 1377-1380
Abstract
Despite recent advances, the structures of many proteins cannot be determined by electron cryomicroscopy because the individual proteins move during irradiation. This blurs the images so that they cannot be aligned with each other to calculate a three-dimensional density. Much of this movement stems from instabilities in the carbon substrates used to support frozen samples in the microscope. Here we demonstrate a gold specimen support that nearly eliminates substrate motion during irradiation. This increases the subnanometer image contrast such that α helices of individual proteins are resolved. With this improvement, we determine the structure of apoferritin, a smooth octahedral shell of α-helical subunits that is particularly difficult to solve by electron microscopy. This advance in substrate design will enable the solution of currently intractable protein structures.Keywords
This publication has 39 references indexed in Scilit:
- Structure of the Yeast Mitochondrial Large Ribosomal SubunitScience, 2014
- Atomic model of the F420-reducing [NiFe] hydrogenase by electron cryo-microscopy using a direct electron detectoreLife, 2014
- Structure of the TRPV1 ion channel determined by electron cryo-microscopyNature, 2013
- Problems in obtaining perfect images by single-particle electron cryomicroscopy of biological structures in amorphous iceMicroscopy, 2013
- Images of paraffin monolayer crystals with perfect contrast: Minimization of beam-induced specimen motionUltramicroscopy, 2011
- Observations on the behavior of vitreous ice at ∼82 and∼12 KJournal of Structural Biology, 2006
- Direct single electron detection with a CMOS detector for electron microscopyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2005
- Optimal Determination of Particle Orientation, Absolute Hand, and Contrast Loss in Single-particle Electron CryomicroscopyJournal of Molecular Biology, 2003
- The potential and limitations of neutrons, electrons and X-rays for atomic resolution microscopy of unstained biological moleculesQuarterly Reviews of Biophysics, 1995
- Quantitative analysis of image contrast in electron micrographs of beam-sensitive crystalsUltramicroscopy, 1985