Differential pulse stripping voltammetric determination of thallium with an 8‐hydroxyquinoline‐modified carbon paste electrode
Authors:
- 1 April 1995
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 7 (4) , 379-385
Abstract
A carbon paste electrode incorporating 8‐hydroxyquinoline was fabricated to selectively accumulate TlI at open circuit. The accumulated TlI, after reduction to metallic thallium at the electrode surface, was anodically stripped by differential pulse voltammetry. Under optimized conditions, TlI concentrations in the range 1.00 × 10−8 M − 1.00 × 10−5 M gave two linear regions due to different controlling factors for accumulation. A detection limit of 4.90 × 10−9 M (1.00 ppb) was found for a 120‐s accumulation. For 10 determinations of TlI at concentrations of 1.00 × 10−6 M and 1.00 × l0−7 M, relative standard deviations of 2.60% and 3.20% were obtained, respectively. Interferences from BiIII, PbII and CuII could be removed by masking with complexing agents such as sodium diethyldithiocarbamate, EDTA, sodium citrate, etc. A method was developed for thallium speciation and analysis, based on the determination of TlI while masking TlIII with EDTA followed by chemical reduction of TlIII to TlI with hydroxylamine hydrochloride. This method was tested using a synthetic sample containing known concentrations of TlI and TlIII.Keywords
This publication has 19 references indexed in Scilit:
- Determination of trace aluminium by differential pulse adsorptive stripping voltammetry of aluminium(II) -8-hydroxyquinoline complexAnalytica Chimica Acta, 1993
- Voltammetric determination of gold using a carbon paste electrode modified with thiobenzanilideThe Analyst, 1993
- Determination of mercury on a carbon paste electrode modified with humic acidElectroanalysis, 1992
- Photoelectrochemical detection and speciation of thallium (I) and thallium (III)Electroanalysis, 1992
- Electroanalysis with electrodes modified by inorganic filmsElectroanalysis, 1991
- Differential pulse voltammetric determination of cobalt with a perfluorinated sulfonated polymer-2,2-bipyridyl modified carbon paste electrodeAnalytical Chemistry, 1991
- Preconcentration and voltammetric measurement of mercury with a crown-ether modified carbon-paste electrodeTalanta, 1988
- Electrochemical masking of large amounts of copper in dpasv and the determination of thallium in the presence of a large excess of copperTalanta, 1985
- Determination of thallium in bismuth by differential pulse anodic-stripping voltammetry without preliminary separationTalanta, 1985
- Carbon paste electrodes modified with cation-exchange resin in differential pulse voltammetryAnalytica Chimica Acta, 1984