Noninvasive identification of the total peripheral resistance baroreflex
- 1 March 2003
- journal article
- clinical trial
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 284 (3) , H947-H959
Abstract
We propose two identification algorithms for quantitating the total peripheral resistance (TPR) baroreflex, an important contributor to short-term arterial blood pressure (ABP) regulation. Each algorithm analyzes beat-to-beat fluctuations in ABP and cardiac output, which may both be obtained noninvasively in humans. For a theoretical evaluation, we applied both algorithms to a realistic cardiovascular model. The results contrasted with only one of the algorithms proving to be reliable. This algorithm was able to track changes in the static gains of both the arterial and cardiopulmonary TPR baroreflex. We then applied both algorithms to a preliminary set of human data and obtained contrasting results much like those obtained from the cardiovascular model, thereby making the theoretical evaluation results more meaningful. This study suggests that, with experimental testing, the reliable identification algorithm may provide a powerful, noninvasive means for quantitating the TPR baroreflex. This study also provides an example of the role that models can play in the development and initial evaluation of algorithms aimed at quantitating important physiological mechanisms.Keywords
This publication has 18 references indexed in Scilit:
- Computational modeling of cardiovascular response to orthostatic stressJournal of Applied Physiology, 2002
- A forward model-based validation of cardiovascular system identificationAmerican Journal of Physiology-Heart and Circulatory Physiology, 2001
- System identification of closed-loop cardiovascular control mechanisms: diabetic autonomic neuropathy.American Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 1999
- Fifteen years experience with finger arterial pressure monitoring: assessment of the technologyCardiovascular Research, 1998
- Improved method for cardiac output determination in man using ultrasound Doppler techniqueMedical & Biological Engineering & Computing, 1990
- Assessment of autonomic response by broad-band respirationIEEE Transactions on Biomedical Engineering, 1989
- End-systolic pressure/volume ratio: A new index of ventricular contractilityThe American Journal of Cardiology, 1977
- Least-squares identification of closed-loop systemsInternational Journal of Control, 1975
- Parameter sensitivity analysis of a network model of systemic circulatory mechanicsAnnals of Biomedical Engineering, 1974
- Characteristics of Aortic Diastolic Pressure Decay with Application to the Continuous Monitoring of Changes in Peripheral Vascular ResistanceCirculation Research, 1974