A Comparative Study of Patient Radiation Dose between Standard Angiogram and Road-Map Technique in Hemodialysis Patients During Fistuloplasty Using Digital Subtraction Angiography
- 15 September 2026
- journal article
- Published by Medical Association of Thailand in Journal of the Medical Association of Thailand
- Vol. 109 (9) , 725
Abstract
Objective: To 1) compare the radiation dose received by patients undergoing hemodialysis vascular access angioplasty using Angiogram mode and Road-map mode, 2) evaluate patient radiation dose relative to the International Atomic Energy Agency (IAEA) trigger levels, and 3) identify technical factors influencing dose variation. Materials and Methods: This retrospective analytical study included 195 patients who underwent hemodialysis vascular access angioplasty at Songklanagarind Hospital between December 2019 and December 2021 (Road-map: 80 patients; Angiogram: 115 patients). Collected parameters included dose area product (DAP), reference point air kerma (Ka,r), kVp, mAs, fluoroscopy time, frame rate, and number of images. Data were analyzed using an independent t-test and a one-sample t-test. Results: Mean DAP and Ka,r in Road-map mode (0.92 Gy·cm² and 3.19 mGy) were significantly higher than Angiogram mode (0.55 Gy·cm² and 1.60 mGy) (p<0.001). Although Road-map mode utilized shorter fluoroscopy time, its fixed higher frame rate (15 fps vs. 2 fps) resulted in greater radiation exposure. Both techniques remained well below IAEA trigger levels. Conclusion: Angiogram mode offers an advantage in minimizing radiation dose, whereas Road-map mode may be preferred when rapid image guidance is required.Keywords
This publication has 11 references indexed in Scilit:
- Low fluoroscopy pulse rates as a mean to reduce radiation exposure during neuroendovascular procedureInterventional Neuroradiology, 2020
- The “As Low As Reasonably Achievable” (ALARA) principle: a brief historical overview and a bibliometric analysis of the most cited publicationsRadioprotection, 2019
- A Review of Percutaneous Transluminal Angioplasty in Hemodialysis FistulaInternational Journal of Vascular Medicine, 2018
- Radiation doses and estimated risk from angiographic projections during coronary angiography performed using novel flat detectorJournal of Applied Clinical Medical Physics, 2016
- Radiation Dose Associated with Dialysis Vascular Access Interventional Procedures in the Interventional Nephrology FacilitySeminars in Dialysis, 2013
- A Dose Ocupacional e a Fluoroscopia Pulsada no Cateterismo Cardíaco2013
- Occupational Radiation Dose:Percutaneous Interventional Procedures on Hemodialysis Arteriovenous Fistulas and GraftsRadiology, 2012
- Radiation Doses from Venous Access ProceduresRadiology, 2006
- Comparison of effective doses obtained from dose–area product and air kerma measurements in interventional radiologyBritish Journal of Radiology, 2004
- Introduction to sample size determination and power analysis for clinical trialsControlled Clinical Trials, 1981