Ejection Wave Segmentation for Contact-Free Heart Rate Estimation from Ballistocardiographic Signals
Authors:
- 1 July 2019
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2019, 3571-3576
Abstract
We present a new algorithm for peak detection in ballistocardiographic (BCG) signals and use it for heart rate estimation. Systolic complexes of the BCG signal are enhanced and coarse heart beat locations estimated. Ejection waves I, J and K are detected simultaneously around coarse locations, only using detection of local maxima and weighted summation of peak heights. Due to a lack of reference BCG annotations, the algorithm’s performance is assessed by using the detected peaks for heart rate estimation. On a dataset acquired with a pneumatic BCG system, we evaluate the heart rate estimation performance and compare the introduced algorithm against other methods found in literature. The dataset is gathered from 42 patients in a clinical environment and provides low-quality signals taken from a realistic scenario. With a mean absolute percentage error of 2.58 % at 65 % coverage, the presented method is on par with the best-performing state-of-the-art algorithms investigated. Limits of agreement (5th/95th percentiles) in a comparison with ECG-based heart rate measurements lie within P 5 = −3.63 and P 95 = 5.78 beat/min.Keywords
This publication has 16 references indexed in Scilit:
- Robust inter-beat interval estimation in cardiac vibration signalsPhysiological Measurement, 2013
- Using ballistocardiography to measure cardiac performance: a brief review of its history and future significanceClinical Physiology and Functional Imaging, 2012
- Slow-wave sleep estimation on a load-cell-installed bed: a non-constrained methodPhysiological Measurement, 2009
- Accelerometer‐Derived Time Intervals during Various Pacing Modes in Patients with Biventricular Pacemakers: Comparison with NormalsPacing and Clinical Electrophysiology, 2007
- BSeg++: A modified Blind Segmentation Method for Ballistocardiogram Cycle Extraction2007
- A new method for measuring the ballistocardiogram using EMFi sensors in a normal chair2007
- New methods for precise detection of systolic complexes in the signal acquired from quantitative seismocardiograph2006
- Noninvasive Measurement of Heartbeat, Respiration, Snoring and Body Movements of a Subject in Bed via a Pneumatic MethodIEEE Transactions on Biomedical Engineering, 2005
- Measuring agreement in method comparison studiesStatistical Methods in Medical Research, 1999
- Proposals for Ballistocardiographic Nomenclature and Conventions: Revised and ExtendedCirculation, 1956