Determination of Tyrosine in the Presence of Sodium Dodecyl Sulfate Using a Gold Nanoparticle Modified Carbon Paste Electrode
- 15 January 2013
- journal article
- research article
- Published by Taylor & Francis in Analytical Letters
- Vol. 46 (2) , 299-311
Abstract
A carbon paste electrode modified with gold nanoparticles (AuMCPE) was used as a highly sensitive sensor for determination of Tyrosine (Tyr), in the presence of an anionic surfactant, sodium dodecyl sulfate (SDS), in aqueous solution. The measurements were carried out by using of differential pulse voltammetry (DPV), cyclic voltammetry (CV), amd chronocoulometry and chronoamperometry methods. The prepared electrode shows voltammetric responses with high sensitivity and selectivity for Tyr in the presence of SDS. The relationship between the oxidation peak current of Tyr and its concentration was obtained linearly and it was 1.0 × 10−7 to 1.0 × 10−5 M with a detection limit of 5.5 × 10−8 M in the absence of SDS. On the other hand the oxidation peak current of Tyr increased significantly at AuMCPE in the presence of SDS and its detection limit was reduced to 2.7 × 10−9 M. The proposed voltammetric approach was also applied to the determination of Tyr concentration in human serum.Keywords
This publication has 31 references indexed in Scilit:
- Central composite rotatable design in the development of a new method for optimization, voltammetric determination and electrochemical behavior of betaxolol in the presence of acetaminophen based on a gold nanoparticle modified electrodeAnalytical Methods, 2012
- Sensitive voltammetric determination of tyrosine using multi-walled carbon nanotubes/4-aminobenzeresulfonic acid film-coated glassy carbon electrodeColloids and Surfaces B: Biointerfaces, 2008
- The adsorption, CMC determination and corrosion inhibition of some N-alkyl quaternary ammonium salts on carbon steel surface in 2M H2SO4Colloids and Surfaces A: Physicochemical and Engineering Aspects, 2006
- Influence of Nafion Coatings and Surfactant on the Stripping Voltammetry of Heavy Metals at Bismuth‐Film Modified Carbon Film ElectrodesElectroanalysis, 2006
- Magnetic Composite Electroplating for Depositing MicromagnetsJournal of Microelectromechanical Systems, 2006
- Gold Nanoparticles: Assembly, Supramolecular Chemistry, Quantum-Size-Related Properties, and Applications toward Biology, Catalysis, and NanotechnologyChemical Reviews, 2003
- Voltammetric behavior and determination of estrogens at Nafion-modified glassy carbon electrode in the presence of cetyltrimethylammonium bromideAnalytica Chimica Acta, 2002
- Nanostructured platinum as an electrocatalyst for the electrooxidation of formic acidJournal of Electroanalytical Chemistry, 2002
- Endothelial Dysfunction, Oxidative Stress, and Risk of Cardiovascular Events in Patients With Coronary Artery DiseaseCirculation, 2001
- Electrocatalytic reactions on carbon fibre electrodes modified by hemine II. Electro-oxidation of hydrazineSynthetic Metals, 1989