High-density versus low-density mapping in ablation of atypical atrial flutter
Authors:
- 17 January 2021
- journal article
- research article
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 62 (3) , 587-599
Abstract
Purpose Ablation of atypical atrial flutter (AAFL) can be challenging. High-density (HD) mapping of ablation targets may potentially increase procedural success and freedom from recurrent AAFL. The objective of the present study was to explore whether employing HD mapping leads to a more favorable outcome in ablation of AAFL. Methods We compared baseline and procedural characteristics, procedural success, safety and outcome of mapping and ablation of atypical flutter in three groups. (1) HD Grid catheter + the high-density electroanatomical mapping (EAM) system EnSite Precision; (2) standard 10-pole circular mapping catheter (CMC) + EnSite Precision; (3) CMC + the low-density EnSite Velocity EAM. Voltage and propagation maps were constructed. Results Mapping of 142 AAFL in 82 patients was performed. Acute ablation success was 78%, 68%, and 51% in groups 1, 2, and 3 (p = 0.037 between group 1 and 3, non-significant between groups otherwise). Moreover, 8%, 27%, and 36% of flutters were unmappable in groups 1, 2, and 3, respectively (p < 0.05 between group 1 and both groups 2 and 3). AAFL recurrence at 1-year FU was 26%, 36%, and 62% in groups 1, 2, and 3 (p = 0.007 between groups 1 and 3, p = 0.05 between groups 2 and 3). AAFL-free survival was significantly higher in patients mapped with Precision than with Velocity (p = 0.011). No strokes or mortality occurred within 30 days. Conclusions Acute procedural success of ablation of atypical atrial flutter is higher and the number of unmappable flutters is lower using the HD Grid mapping catheter in combination with the high-density EnSite Precision system, as compared to a decapolar circular mapping catheter and the low-density EnSite Velocity EAM system. This may lead to increased freedom from recurrent AAFL at 1 year. HD mapping is safe.Keywords
This publication has 38 references indexed in Scilit:
- Inverse Relationship Between Fractionated Electrograms and Atrial Fibrosis in Persistent Atrial FibrillationJACC, 2013
- Catheter ablation of scar-related atypical atrial flutterEP Europace, 2013
- Higher Rate of Recurrent Atrial Flutter and Atrial Fibrillation Following Atrial Flutter Ablation After Cardiac SurgeryJournal of Cardiovascular Electrophysiology, 2010
- Circumferential Pulmonary Vein Ablation With Additional Linear Ablation Results in an Increased Incidence of Left Atrial Flutter Compared With Segmental Pulmonary Vein Isolation as an Initial Approach to Ablation of Paroxysmal Atrial FibrillationCirculation: Arrhythmia and Electrophysiology, 2010
- Peri-mitral atrial flutter in patients with atrial fibrillation ablationHeart Rhythm, 2010
- Atrial Tachycardias Encountered in the Context of Catheter Ablation for Atrial Fibrillation Part II: Mapping and AblationPacing and Clinical Electrophysiology, 2009
- Proarrhythmic Aspects of Atrial Fibrillation SurgeryCirculation, 2008
- Left atrial tachycardia after circumferential pulmonary vein ablation for atrial fibrillation: incidence, electrophysiological characteristics, and results of radiofrequency ablationEP Europace, 2006
- Proarrhythmia of Circumferential Left Atrial Lesions for Management of Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2005
- Left Septal Atrial FlutterCirculation, 2004